Pipe conductance & pump speed / Worked example
Viscous Dry Pump Header
A 22 mm tube carries air at mean pressure 350 Pa over 0.85 m to a dry pump.
Inputs
Gas and series restriction
Live readout
Viscous / continuum- Molecular conductance
- 1.468 L/s
- Laminar conductance model
- 130.6 L/s
- Molecular transmission
- 3.336%
- Knudsen number Kn
- 8.88e-4
- Regime-adjusted tube conductance
- 130.6 L/s
- Total series conductance
- 130.6 L/s
- Effective chamber speed
- 7.538 L/s
- Pump utilization
- 94.23%
- Minimum inside diameter for 80%
- 15.48 mm
Reading this example
Viscous conductance varies with mean pressure. Re-check the header later in roughing as density falls.
Model & assumptions
Tube throughput
Cₘ = (A v̄/4) / (1 + 3L/4D) · Cᵥ = πD⁴P̄/(128ηL)
The aperture-to-long-tube resistance approximation approaches Clausing’s long-tube limit. It is a simplified short-tube correction. The viscous model assumes isothermal, fully developed laminar flow.
Chamber speed
1/Cₜ = 1/C + 1/C₂ · 1/Sₑ = 1/Sₚ + 1/Cₜ
Transition uses a logarithmic Knudsen weight between the two limits. The 80% search requires Cₜ ≥ 4Sₚ. A fixed series restriction at or below 4Sₚ makes the 80% target unattainable by enlarging the tube alone.