Flange load & viewport stress / Worked example
Axial Gland Fill Above the Screen
A fused silica carrier has an adequate plate but a narrow axial O-ring gland, giving high fill below the physical capacity limit.
Inputs
Seal and gland
Live readout
O-ring gland screen fail- Pressure differential
- 1.013e5 Pa
- Atmospheric resultant
- 877.4 N
- Resultant per fastener (equal share)
- 146.2 N
- Peak bending stress
- 3.01 MPa
- Screening allowable stress
- 9.6 MPa
- Center deflection
- 2.331e-3 mm
- Material safety factor
- 15.95
- Required safety factor
- 5
- O-ring squeeze
- 22.1%
- O-ring gland fill
- 87.87%
- Check assembled gland geometry against 15–30% squeeze and below 85% fill.
Reading this example
Squeeze can pass while fill fails. Increasing gland width changes volume without changing nominal squeeze.
Model & assumptions
Atmospheric resultant
F = ΔP πDseal²/4
The atmosphere usually seats an evacuated assembly. Equal force per fastener is a load share only. Determine bolt preload, clamp and flange ratings from the assembly design.
Circular plate
σsimple = 3(3+ν)ΔPr²/(8t²) · σclamped = 3ΔPr²/(4t²)
The simple-support maximum is at the center. For an ideal clamp, maximum bending is at the edge. Deflection follows small-deflection thin-plate theory. The screen uses safety factor 4 for steel and 5 for brittle viewports.
Elastomer gland
Squeeze = 1 − h/d · Fill = (πd²/4)/(hw)
Use assembled clearance h for axial or radial compression. The screen accepts 15% to 30% squeeze and fill below 85%. Fill at or above 100% exceeds the modeled gland capacity. CF copper gasket checks use assembly data.