Flange load & viewport stress / Worked example

CF Fused Silica Viewport

A CF copper-gasket carrier holds a 6 mm fused silica disk over a 76 mm unsupported opening.

Readout ↓

Inputs

Plate and atmospheric load
Pa
Pa
mm
mm
mm
MPa
Enter 0 for a clamp or to omit equal load sharing.
Seal and gland

Live readout

Viewport and seal screen pass
Net force616.3NBending stress3.048MPaDeflection2.474e-3mmSafety factor15.75Seal Ø 88 mmViewport safety factorCF metal gasketActual SF15.7Minimum SF5SealCopper
Pressure differential
1.013e5 Pa
Atmospheric resultant
616.3 N
Resultant per fastener (equal share)
77.03 N
Peak bending stress
3.048 MPa
Screening allowable stress
9.6 MPa
Center deflection
2.474e-3 mm
Material safety factor
15.75
Required safety factor
5
O-ring squeeze
CF metal seal
O-ring gland fill
CF metal seal

    Reading this example

    The seal diameter sets net force. The smaller unsupported opening sets plate bending and deflection.

    Model & assumptions

    Atmospheric resultant

    F = ΔP πDseal²/4

    The atmosphere usually seats an evacuated assembly. Equal force per fastener is a load share only. Determine bolt preload, clamp and flange ratings from the assembly design.

    Circular plate

    σsimple = 3(3+ν)ΔPr²/(8t²) · σclamped = 3ΔPr²/(4t²)

    The simple-support maximum is at the center. For an ideal clamp, maximum bending is at the edge. Deflection follows small-deflection thin-plate theory. The screen uses safety factor 4 for steel and 5 for brittle viewports.

    Elastomer gland

    Squeeze = 1 − h/d · Fill = (πd²/4)/(hw)

    Use assembled clearance h for axial or radial compression. The screen accepts 15% to 30% squeeze and fill below 85%. Fill at or above 100% exceeds the modeled gland capacity. CF copper gasket checks use assembly data.