Flange load & viewport stress / Worked example

ISO-KF Borosilicate Viewport and Gland

A small borosilicate window uses a 3.53 mm O-ring in a 2.8 mm high axial gland.

Readout ↓

Inputs

Plate and atmospheric load
Pa
Pa
mm
mm
mm
MPa
Enter 0 for a clamp or to omit equal load sharing.
Seal and gland
mm
mm
mm

Live readout

Viewport and seal screen pass
Net force267.7NBending stress1.9MPaDeflection8.015e-4mmSafety factor13.16Seal Ø 58 mmViewport safety factorSeal squeeze / gland fillActual SF13.2Minimum SF5Gland fill76%
Pressure differential
1.013e5 Pa
Atmospheric resultant
267.7 N
Resultant per fastener (equal share)
66.93 N
Peak bending stress
1.9 MPa
Screening allowable stress
5 MPa
Center deflection
8.015e-4 mm
Material safety factor
13.16
Required safety factor
5
O-ring squeeze
20.68%
O-ring gland fill
75.98%

    Reading this example

    Check atmospheric stress and gland volume together. A nominally adequate squeeze can still leave too little free volume.

    Model & assumptions

    Atmospheric resultant

    F = ΔP πDseal²/4

    The atmosphere usually seats an evacuated assembly. Equal force per fastener is a load share only. Determine bolt preload, clamp and flange ratings from the assembly design.

    Circular plate

    σsimple = 3(3+ν)ΔPr²/(8t²) · σclamped = 3ΔPr²/(4t²)

    The simple-support maximum is at the center. For an ideal clamp, maximum bending is at the edge. Deflection follows small-deflection thin-plate theory. The screen uses safety factor 4 for steel and 5 for brittle viewports.

    Elastomer gland

    Squeeze = 1 − h/d · Fill = (πd²/4)/(hw)

    Use assembled clearance h for axial or radial compression. The screen accepts 15% to 30% squeeze and fill below 85%. Fill at or above 100% exceeds the modeled gland capacity. CF copper gasket checks use assembly data.