Worked example
Heat Pump Water Heater Savings in an All-Electric Home
An electric-resistance water heater serves 50 hot gallons on a typical day. The replacement quote uses a 3.6 UEF hybrid, $0.18/kWh electricity and a $1,400 installation premium.
Try it Try a winter inlet of 42°F at the same daily volume. Compare the annual heat and cost for both heaters, then check the selected unit at its planned location.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Required first-hour hot volume
- US gal
- Tankless outlet flow at peak
- US gal/min
- Heat pump savings / year
- USD
Compare storage FHR and tankless flow at the entered water temperature rise.
Peak draw & annual operating cost
- Required temperature rise
- °F
- Tankless delivered heating power
- Btu/h
- Useful water heat / year
- MMBtu
- Electric storage bill / year
- USD
- Gas storage bill / year
- USD
- Gas tankless bill / year
- USD
- Heat pump bill / year
- USD
- Heat pump simple payback
- years
Inputs used
- Incoming cold water temperature
- 50 °F
- Heater outlet temperature
- 120 °F
- Mixed temperature at showers, tub or sink
- 105 °F
- Typical daily volume at heater outlet temperature
- 50 US gal
- Shower 1 · Fixture flow
- 2 US gal/min
- Shower 1 · Draw duration
- 10 min
- Shower 1 · Start within peak hour
- 0 min
- Shower 2 · Fixture flow
- 2 US gal/min
- Shower 2 · Draw duration
- 10 min
- Shower 2 · Start within peak hour
- 10 min
- Tub or sink · Fixture flow
- 1.2 US gal/min
- Tub or sink · Draw duration
- 5 min
- Tub or sink · Start within peak hour
- 18 min
- Hot-only appliance · Fixture flow
- 1.5 US gal/min
- Hot-only appliance · Draw duration
- 4 min
- Hot-only appliance · Start within peak hour
- 35 min
- Existing heater type
- Electric storage
- Electricity rate
- 0.18 $/kWh
- Natural gas rate
- 1.45 $/therm
- Electric storage UEF
- 0.9
- Gas storage UEF
- 0.64
- Gas tankless UEF
- 0.92
- Hybrid heat-pump UEF
- 3.6
- Net extra heat-pump installation cost
- 1,400 USD
How this calculation works
Convert mixed fixture flow to heater outlet flow with (T_mixed − T_cold) ÷ (T_hot − T_cold). The hot-only appliance uses its full entered flow. Sum hot flow × minutes to get the required first-hour hot-water volume.
Overlapping draws add together. Report the largest concurrent outlet flow at the entered temperature rise, and calculate its delivered thermal power. Compare tankless units at that flow and rise, and storage units against rated FHR at their test conditions.
Annual useful heat is 8.34 Btu per US gallon per °F × typical daily hot volume × the temperature rise × 365. Divide by the entered UEF and apply the fuel price. Use UEF ratings representative of the usage bin and installation.
This operating-cost estimate holds demand and utility rates constant. It excludes standby recirculation beyond the rating, room heat exchange, service charges, maintenance and plumbing losses.
References
Frequently asked questions
Can the 3.6 UEF heat pump heater use one-quarter of the resistance energy?
For the same delivered heat and rated operation, the ratio is 0.90 divided by 3.6, or one-quarter. Installation and selected mode can shift actual use.
Why enter 50 hot gallons instead of copying the first-hour result?
Typical daily usage drives yearly energy. First-hour demand is an equipment sizing check for an unusually busy hour.