Deep Tub and Shower in One Peak Hour

A 5 gpm tub fills for nine minutes, then a 2 gpm shower starts at minute twelve and lasts ten minutes. The water is mixed to 104°F with 55°F cold water and a 125°F heater outlet.

Try it Move the shower start to minute five to test simultaneous use. Compare the peak tankless demand without changing the total hot volume.

Water temperature and usage
°F
°F
°F
US gal
Shower 1
US gal/min
min
min
Shower 2
US gal/min
min
min
Tub or sink
US gal/min
min
min
Hot-only appliance
US gal/min
min
min
Operating cost
$/kWh
$/therm
USD
Required first-hour hot volume
45.5 US gal
Tankless outlet flow at peak
3.5 US gal/min
Heat pump savings / year
384.29 USD

Compare storage FHR and tankless flow at the entered water temperature rise.

Peak draw & annual operating cost

Peak hot-water flow and modeled annual billsPeak flow 3.5 US gal/min. First-hour hot volume 45.5 US gal. Heat pump annual bill 137.03 USD. Hot outlet flow · US gal/min024015304560 minAnnual operating cost · USDElectric tank$521Gas tank$232Gas tankless$161Heat pump$137
The step chart adds overlapping hot-side fixture flows. The bars show modeled annual energy cost at the entered rates.
Required temperature rise
70 °F
Tankless delivered heating power
122,598 Btu/h
Useful water heat / year
10.228 MMBtu
Electric storage bill / year
521.32 USD
Gas storage bill / year
231.73 USD
Gas tankless bill / year
161.2 USD
Heat pump bill / year
137.03 USD
Heat pump simple payback
4 years
Download

How this calculation works

Convert mixed fixture flow to heater outlet flow with (T_mixed − T_cold) ÷ (T_hot − T_cold). The hot-only appliance uses its full entered flow. Sum hot flow × minutes to get the required first-hour hot-water volume.

Overlapping draws add together. Report the largest concurrent outlet flow at the entered temperature rise, and calculate its delivered thermal power. Compare tankless units at that flow and rise, and storage units against rated FHR at their test conditions.

Annual useful heat is 8.34 Btu per US gallon per °F × typical daily hot volume × the temperature rise × 365. Divide by the entered UEF and apply the fuel price. Use UEF ratings representative of the usage bin and installation.

This operating-cost estimate holds demand and utility rates constant. It excludes standby recirculation beyond the rating, room heat exchange, service charges, maintenance and plumbing losses.

References

Frequently asked questions

Why does a 45-gallon tub draw only count as 31.5 hot gallons here?

At these temperatures, 70% of the tub mixture comes from the heater. Multiply the tub’s 45 gallons by 0.70.

Does the storage heater have to hold 45.5 gallons for this tub-and-shower schedule?

Compare the 45.5-gallon demand with first-hour delivery, which includes recovery. Check the manufacturer’s actual recovery at your inlet temperature and chosen mode.