Worked example
Deep Tub and Shower in One Peak Hour
A 5 gpm tub fills for nine minutes, then a 2 gpm shower starts at minute twelve and lasts ten minutes. The water is mixed to 104°F with 55°F cold water and a 125°F heater outlet.
Try it Move the shower start to minute five to test simultaneous use. Compare the peak tankless demand without changing the total hot volume.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Required first-hour hot volume
- US gal
- Tankless outlet flow at peak
- US gal/min
- Heat pump savings / year
- USD
Compare storage FHR and tankless flow at the entered water temperature rise.
Peak draw & annual operating cost
- Required temperature rise
- °F
- Tankless delivered heating power
- Btu/h
- Useful water heat / year
- MMBtu
- Electric storage bill / year
- USD
- Gas storage bill / year
- USD
- Gas tankless bill / year
- USD
- Heat pump bill / year
- USD
- Heat pump simple payback
- years
Inputs used
- Incoming cold water temperature
- 55 °F
- Heater outlet temperature
- 125 °F
- Mixed temperature at showers, tub or sink
- 104 °F
- Typical daily volume at heater outlet temperature
- 48 US gal
- Shower 1 · Fixture flow
- 2 US gal/min
- Shower 1 · Draw duration
- 10 min
- Shower 1 · Start within peak hour
- 12 min
- Shower 2 · Fixture flow
- 0 US gal/min
- Shower 2 · Draw duration
- 10 min
- Shower 2 · Start within peak hour
- 10 min
- Tub or sink · Fixture flow
- 5 US gal/min
- Tub or sink · Draw duration
- 9 min
- Tub or sink · Start within peak hour
- 0 min
- Hot-only appliance · Fixture flow
- 0 US gal/min
- Hot-only appliance · Draw duration
- 4 min
- Hot-only appliance · Start within peak hour
- 35 min
- Existing heater type
- Electric storage
- Electricity rate
- 0.16 $/kWh
- Natural gas rate
- 1.45 $/therm
- Electric storage UEF
- 0.92
- Gas storage UEF
- 0.64
- Gas tankless UEF
- 0.92
- Hybrid heat-pump UEF
- 3.5
- Net extra heat-pump installation cost
- 1,550 USD
How this calculation works
Convert mixed fixture flow to heater outlet flow with (T_mixed − T_cold) ÷ (T_hot − T_cold). The hot-only appliance uses its full entered flow. Sum hot flow × minutes to get the required first-hour hot-water volume.
Overlapping draws add together. Report the largest concurrent outlet flow at the entered temperature rise, and calculate its delivered thermal power. Compare tankless units at that flow and rise, and storage units against rated FHR at their test conditions.
Annual useful heat is 8.34 Btu per US gallon per °F × typical daily hot volume × the temperature rise × 365. Divide by the entered UEF and apply the fuel price. Use UEF ratings representative of the usage bin and installation.
This operating-cost estimate holds demand and utility rates constant. It excludes standby recirculation beyond the rating, room heat exchange, service charges, maintenance and plumbing losses.
References
Frequently asked questions
Why does a 45-gallon tub draw only count as 31.5 hot gallons here?
At these temperatures, 70% of the tub mixture comes from the heater. Multiply the tub’s 45 gallons by 0.70.
Does the storage heater have to hold 45.5 gallons for this tub-and-shower schedule?
Compare the 45.5-gallon demand with first-hour delivery, which includes recovery. Check the manufacturer’s actual recovery at your inlet temperature and chosen mode.