Worked example
Storage and Tankless Sizing for Two Overlapping Showers
Two 2 gpm showers run for ten minutes each, starting at minutes zero and five. The heater outlet is 120°F, the winter inlet is 50°F and the two fixtures mix to 105°F.
Try it Stagger the second shower to start at minute ten. The first-hour volume stays the same, but the peak tankless flow drops.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Required first-hour hot volume
- US gal
- Tankless outlet flow at peak
- US gal/min
- Heat pump savings / year
- USD
Compare storage FHR and tankless flow at the entered water temperature rise.
Peak draw & annual operating cost
- Required temperature rise
- °F
- Tankless delivered heating power
- Btu/h
- Useful water heat / year
- MMBtu
- Electric storage bill / year
- USD
- Gas storage bill / year
- USD
- Gas tankless bill / year
- USD
- Heat pump bill / year
- USD
- Heat pump simple payback
- years
Inputs used
- Incoming cold water temperature
- 50 °F
- Heater outlet temperature
- 120 °F
- Mixed temperature at showers, tub or sink
- 105 °F
- Typical daily volume at heater outlet temperature
- 48 US gal
- Shower 1 · Fixture flow
- 2 US gal/min
- Shower 1 · Draw duration
- 10 min
- Shower 1 · Start within peak hour
- 0 min
- Shower 2 · Fixture flow
- 2 US gal/min
- Shower 2 · Draw duration
- 10 min
- Shower 2 · Start within peak hour
- 5 min
- Tub or sink · Fixture flow
- 0 US gal/min
- Tub or sink · Draw duration
- 5 min
- Tub or sink · Start within peak hour
- 18 min
- Hot-only appliance · Fixture flow
- 0 US gal/min
- Hot-only appliance · Draw duration
- 4 min
- Hot-only appliance · Start within peak hour
- 35 min
- Existing heater type
- Electric storage
- Electricity rate
- 0.16 $/kWh
- Natural gas rate
- 1.45 $/therm
- Electric storage UEF
- 0.92
- Gas storage UEF
- 0.64
- Gas tankless UEF
- 0.92
- Hybrid heat-pump UEF
- 3.5
- Net extra heat-pump installation cost
- 1,550 USD
How this calculation works
Convert mixed fixture flow to heater outlet flow with (T_mixed − T_cold) ÷ (T_hot − T_cold). The hot-only appliance uses its full entered flow. Sum hot flow × minutes to get the required first-hour hot-water volume.
Overlapping draws add together. Report the largest concurrent outlet flow at the entered temperature rise, and calculate its delivered thermal power. Compare tankless units at that flow and rise, and storage units against rated FHR at their test conditions.
Annual useful heat is 8.34 Btu per US gallon per °F × typical daily hot volume × the temperature rise × 365. Divide by the entered UEF and apply the fuel price. Use UEF ratings representative of the usage bin and installation.
This operating-cost estimate holds demand and utility rates constant. It excludes standby recirculation beyond the rating, room heat exchange, service charges, maintenance and plumbing losses.
References
Frequently asked questions
Why does shifting the showers change tankless flow but leave FHR alone?
The peak flow adds fixtures that run at the same moment. The first-hour hot volume adds all draws in the hour, regardless of overlap.
Are the two shower-head flow rates the tankless heater flow?
The heater only supplies the hot portion mixed with incoming cold water. The case uses 55/70 of each shower flow on the hot side.