Tankless Winter Demand with Showers and an Appliance

A cold region drops to a 38°F water inlet. Two 1.8 gpm showers start at minute two, and an appliance draws 1.2 gpm of full-hot water during part of that same interval.

Try it Move the hot-only appliance to minute fifteen. Compare the peak delivery power at 82°F rise before and after staggering.

Water temperature and usage
°F
°F
°F
US gal
Shower 1
US gal/min
min
min
Shower 2
US gal/min
min
min
Tub or sink
US gal/min
min
min
Hot-only appliance
US gal/min
min
min
Operating cost
$/kWh
$/therm
USD
Required first-hour hot volume
29 US gal
Tankless outlet flow at peak
3.92 US gal/min
Heat pump savings / year
28.32 USD

Compare storage FHR and tankless flow at the entered water temperature rise.

Peak draw & annual operating cost

Peak hot-water flow and modeled annual billsPeak flow 3.92 US gal/min. First-hour hot volume 29 US gal. Heat pump annual bill 160.52 USD. Hot outlet flow · US gal/min024015304560 minAnnual operating cost · USDElectric tank$611Gas tank$271Gas tankless$189Heat pump$161
The step chart adds overlapping hot-side fixture flows. The bars show modeled annual energy cost at the entered rates.
Required temperature rise
82 °F
Tankless delivered heating power
160,929 Btu/h
Useful water heat / year
11.982 MMBtu
Electric storage bill / year
610.69 USD
Gas storage bill / year
271.46 USD
Gas tankless bill / year
188.84 USD
Heat pump bill / year
160.52 USD
Heat pump simple payback
54.7 years
Download

How this calculation works

Convert mixed fixture flow to heater outlet flow with (T_mixed − T_cold) ÷ (T_hot − T_cold). The hot-only appliance uses its full entered flow. Sum hot flow × minutes to get the required first-hour hot-water volume.

Overlapping draws add together. Report the largest concurrent outlet flow at the entered temperature rise, and calculate its delivered thermal power. Compare tankless units at that flow and rise, and storage units against rated FHR at their test conditions.

Annual useful heat is 8.34 Btu per US gallon per °F × typical daily hot volume × the temperature rise × 365. Divide by the entered UEF and apply the fuel price. Use UEF ratings representative of the usage bin and installation.

This operating-cost estimate holds demand and utility rates constant. It excludes standby recirculation beyond the rating, room heat exchange, service charges, maintenance and plumbing losses.

References

Frequently asked questions

Why compare tankless flow at an 82°F rise for this winter house?

The heater raises 38°F incoming water to a 120°F outlet. Capacity in gallons per minute drops as the required temperature rise increases for the same heater output.

Does the dishwasher or appliance use the shower mixing ratio in this case?

The hot-only fixture is modeled as drawing entirely from the heater outlet. Enter its actual inlet flow and duration for the schedule you are screening.