Worked example
Tankless Winter Demand with Showers and an Appliance
A cold region drops to a 38°F water inlet. Two 1.8 gpm showers start at minute two, and an appliance draws 1.2 gpm of full-hot water during part of that same interval.
Try it Move the hot-only appliance to minute fifteen. Compare the peak delivery power at 82°F rise before and after staggering.
Results
Back to inputs ↑Enter valid inputs to calculate results and draw the diagram.
- Required first-hour hot volume
- US gal
- Tankless outlet flow at peak
- US gal/min
- Heat pump savings / year
- USD
Compare storage FHR and tankless flow at the entered water temperature rise.
Peak draw & annual operating cost
- Required temperature rise
- °F
- Tankless delivered heating power
- Btu/h
- Useful water heat / year
- MMBtu
- Electric storage bill / year
- USD
- Gas storage bill / year
- USD
- Gas tankless bill / year
- USD
- Heat pump bill / year
- USD
- Heat pump simple payback
- years
Inputs used
- Incoming cold water temperature
- 38 °F
- Heater outlet temperature
- 120 °F
- Mixed temperature at showers, tub or sink
- 100 °F
- Typical daily volume at heater outlet temperature
- 48 US gal
- Shower 1 · Fixture flow
- 1.8 US gal/min
- Shower 1 · Draw duration
- 8 min
- Shower 1 · Start within peak hour
- 2 min
- Shower 2 · Fixture flow
- 1.8 US gal/min
- Shower 2 · Draw duration
- 8 min
- Shower 2 · Start within peak hour
- 2 min
- Tub or sink · Fixture flow
- 0 US gal/min
- Tub or sink · Draw duration
- 5 min
- Tub or sink · Start within peak hour
- 18 min
- Hot-only appliance · Fixture flow
- 1.2 US gal/min
- Hot-only appliance · Draw duration
- 6 min
- Hot-only appliance · Start within peak hour
- 5 min
- Existing heater type
- Gas tankless
- Electricity rate
- 0.16 $/kWh
- Natural gas rate
- 1.45 $/therm
- Electric storage UEF
- 0.92
- Gas storage UEF
- 0.64
- Gas tankless UEF
- 0.92
- Hybrid heat-pump UEF
- 3.5
- Net extra heat-pump installation cost
- 1,550 USD
How this calculation works
Convert mixed fixture flow to heater outlet flow with (T_mixed − T_cold) ÷ (T_hot − T_cold). The hot-only appliance uses its full entered flow. Sum hot flow × minutes to get the required first-hour hot-water volume.
Overlapping draws add together. Report the largest concurrent outlet flow at the entered temperature rise, and calculate its delivered thermal power. Compare tankless units at that flow and rise, and storage units against rated FHR at their test conditions.
Annual useful heat is 8.34 Btu per US gallon per °F × typical daily hot volume × the temperature rise × 365. Divide by the entered UEF and apply the fuel price. Use UEF ratings representative of the usage bin and installation.
This operating-cost estimate holds demand and utility rates constant. It excludes standby recirculation beyond the rating, room heat exchange, service charges, maintenance and plumbing losses.
References
Frequently asked questions
Why compare tankless flow at an 82°F rise for this winter house?
The heater raises 38°F incoming water to a 120°F outlet. Capacity in gallons per minute drops as the required temperature rise increases for the same heater output.
Does the dishwasher or appliance use the shower mixing ratio in this case?
The hot-only fixture is modeled as drawing entirely from the heater outlet. Enter its actual inlet flow and duration for the schedule you are screening.