WeibullMTBFLab · Engineering calculation
Pump depot transient availability
A repair shop expects 1,200 hours of mean uptime and 16 hours of repair time with no separate logistics delay. Check the first two hours.
Operational availability falls below SLA
Inputs
- Mean uptime MTBF
- 1,200 h
- Corrective repair MTTR
- 16 h
- Additional downtime MDT
- 0 h
- SLA target
- 99.5 %
- Mission time
- 2 h
Results
- Inherent Aᵢ
- 98.68421053 %
- Operational Aₒ
- 98.68421053 %
- Downtime/yr
- 115.2632 h/yr
- Transient A(t)
- 99.84345697 %
- Annual downtime
- 6,915.789 min/yr
- Annual SLA budget
- 43.8 h/yr
- SLA headroom
- -71.46316 h/yr
- Operational SLA tier
- 1 nines
Aᵢ = MTBF / (MTBF + MTTR)Corrective repair alone gives 98.68421053%.Aₒ = MTBF / (MTBF + MTTR + MDT)Additional downtime brings operational availability to 98.68421053%.Downtime/yr = 8,760 (1 − Aₒ)Annual downtime is 115.2632 hours or 6,915.789 minutes.A(t) = Aᵢ + (1−Aᵢ) exp[−(1/MTBF + 1/MTTR)t]Starting fully up, transient availability at 2 h is 99.84345697%.
MTBF is mean uptime, excluding downtime. Enter only additional preventive and logistics downtime per uptime cycle in MDT. The two-state Markov model uses exponential up and repair durations.