Arrhenius & Peck Accelerated Life Testing

Convert temperature and optional humidity stress into equivalent field exposure. Calculate the one-sided zero-failure FIT bound.

Inputs

eV
°C
°C
h
0–1
PassStress accelerates modeled exposure
Combined AF
77.6454×
Field age
77,645.4h
Fleet exposure
5,978,690device·h
Upper FIT
385.132

Acceleration by chamber temperature

Acceleration factor versus stress temperatureAcceleration · log₁₀ AF-0.21.12.395583111139Chamber temperature (°C)TemperatureAF = 1

Both curves share the field temperature and activation energy. The combined curve holds the entered humidity conditions fixed.

Download

Detailed results

Temperature AF
77.64538 ×
Humidity AF
1 ×
Field age per device
8.863628 yr
Pooled field exposure
682.4994 device·yr
Confidence CL
0.9

Formula trace

  1. AFₜ = exp[(Eₐ / k) (1/Tuse − 1/Tstress)]Use 328.15 K and stress 398.15 K give 77.64538×.
  2. AFᵣₕ = (RHstress / RHuse)ⁿThe temperature-only model uses AFᵣₕ = 1.
  3. AF = AFₜ AFᵣₕ · Tpool = AF × time × devicesThe chamber run gives 77,645.38 h per device and 5,978,694 pooled device-hours.
  4. FITᵤ = 10⁹ [−ln(1−CL)] / TpoolThe upper zero-failure bound is 385.1318 FIT.

Model assumptions

Equivalent exposure assumes the same failure mechanism at both stress levels. The FIT bound assumes zero failures, a constant rate for that mechanism and pooled exposure from independent devices.

Method and sources

Worked examples