WeldMetalLab

AWS D1.1 · AISC 360

E70 longitudinal fillet under LRFD

A six-inch longitudinal E70 fillet is checked for a factored 20 kip demand along the weld axis.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Weld and load
in
in
°
Use the increase only where the governing specification permits it.
kip
Leg limits
in
in

Live weld sheet

Updated from inputs
Fillet throat and forceEffective throat 0.177 in. LRFD resistance 33.41 kip. ASD allowable load 22.27 kip. Applied direction factor 1 THROAT0.177inLRFD33.41kipASD22.27kipLOAD FACTOR1 FILLET THROAT AND FORCE Leg 0.25 inLoad angle 0 °E70xx LEG & WELD LOADPASS
Pass · within screen

Leg & weld load · 0.188 in to 0.438 in · 59.9 % load utilization.

Result details

Effective throat0.177 in
LRFD resistance33.41 kip
ASD allowable load22.27 kip
Applied direction factor1
Nominal 0.707 × leg0.177 in
Effective weld length6 in
Effective throat area1.06 in²
Electrode classification strength70 ksi
Angle-only factor1
Nominal weld-metal resistance44.54 kip
Governing plate thickness0.5 in
Minimum nominal leg0.188 in
Maximum edge leg0.438 in
Demand / applicable resistance59.9 %
Weld-metal load margin13.41 kip

Worked example

Starting inputs

Equal leg size
0.25 in
Weld length
6 in
Angle to weld axis
0 °
Weld load demand
20 kip
Welded edge plate
0.5 in
Opposite plate
0.625 in
Minimum leg table
AISC J2.4

Baseline results

Effective throat
0.177 in
LRFD resistance
33.41 kip
ASD allowable load
22.27 kip
Applied direction factor
1

The 0.177 in effective throat over 6 in gives 1.06 in² of weld area. With direction factor 1, compare the 13.41 kip signed resistance margin with zero.

Try it. The angle-only factor is 1.00 along the seam. Compare the LRFD result with factored demand.

Calculation method

tₑ = 0.707w · LRFD = 0.75(0.60FEXX)tₑLₑk · ASD = 0.30FEXX·tₑLₑk

The angle θ is measured from the weld axis. The angle-only factor is 1 + 0.50·sin¹·⁵θ. Use 1.00 unless the selected weld condition permits the increase. Check strain compatibility for the actual weld group. AISC limits effective leg to L/4 for a short weld. For end loading, β reduces length above L/w = 100 and effective length is limited to 180w beyond L/w = 300.

The AWS screen uses the thinner piece for low-hydrogen welding and the thicker piece for the non-low-hydrogen case without qualified crack-prevention preheat. The latter case carries a single-pass condition. AISC uses the thinner piece. AWS cyclic service adds its separate minimum. The conservative edge maximum reserves 2 mm or 1/16 in at and above the corresponding quarter-inch class threshold.

The table basis fixes the inch or metric series even when you switch display units. The capacity is for one straight weld and weld metal only. Check base-metal limit states, eccentricity, fatigue and any qualified joint exceptions separately.

References