End-loaded fillet with length reduction

A long nominal 3/16 in fillet transfers load from the end of a plate. Its physical length is 48 in.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Weld and load
in
in
°
Use the increase only where the governing specification permits it.
kip
Leg limits
in
in

Live weld sheet

Updated from inputs
Fillet throat and forceEffective throat 0.133 in. LRFD resistance 137.9 kip. ASD allowable load 91.93 kip. Applied direction factor 1 THROAT0.133inLRFD137.9kipASD91.93kipLOAD FACTOR1 FILLET THROAT AND FORCE Leg 0.188 inLoad angle 0 °E70xx LEG & WELD LOADPASS
Pass · within screen

Leg & weld load · 0.188 in to 0.313 in · 72.5 % load utilization.

Result details

Effective throat0.133 in
LRFD resistance137.9 kip
ASD allowable load91.93 kip
Applied direction factor1
Nominal 0.707 × leg0.133 in
Effective weld length33.02 in
Effective throat area4.38 in²
Electrode classification strength70 ksi
Angle-only factor1
Nominal weld-metal resistance183.87 kip
Governing plate thickness0.38 in
Minimum nominal leg0.188 in
Maximum edge leg0.313 in
Demand / applicable resistance72.5 %
Weld-metal load margin37.9 kip

Worked example

Starting inputs

Equal leg size
0.1875 in
Weld length
48 in
Angle to weld axis
0 °
Length condition
End loaded
Demand basis
LRFD factored
Weld load demand
100 kip
Welded edge plate
0.375 in

Baseline results

Effective throat
0.133 in
LRFD resistance
137.9 kip
ASD allowable load
91.93 kip
Applied direction factor
1

The 0.133 in effective throat over 33.02 in gives 4.38 in² of weld area. With direction factor 1, compare the 37.9 kip signed resistance margin with zero.

Try it. The effective length is shorter than the physical weld because the end-loaded length-to-leg ratio exceeds 100.

Calculation method

tₑ = 0.707w · LRFD = 0.75(0.60FEXX)tₑLₑk · ASD = 0.30FEXX·tₑLₑk

The angle θ is measured from the weld axis. The angle-only factor is 1 + 0.50·sin¹·⁵θ. Use 1.00 unless the selected weld condition permits the increase. Check strain compatibility for the actual weld group. AISC limits effective leg to L/4 for a short weld. For end loading, β reduces length above L/w = 100 and effective length is limited to 180w beyond L/w = 300.

The AWS screen uses the thinner piece for low-hydrogen welding and the thicker piece for the non-low-hydrogen case without qualified crack-prevention preheat. The latter case carries a single-pass condition. AISC uses the thinner piece. AWS cyclic service adds its separate minimum. The conservative edge maximum reserves 2 mm or 1/16 in at and above the corresponding quarter-inch class threshold.

The table basis fixes the inch or metric series even when you switch display units. The capacity is for one straight weld and weld metal only. Check base-metal limit states, eccentricity, fatigue and any qualified joint exceptions separately.

References

More worked examples