AWS D1.1 · AISC 360
End-loaded fillet with length reduction
A long nominal 3/16 in fillet transfers load from the end of a plate. Its physical length is 48 in.
Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.
Inputs
Live weld sheet
Updated from inputsLeg & weld load · 0.188 in to 0.313 in · 72.5 % load utilization.
Result details
| Effective throat | 0.133 in |
|---|---|
| LRFD resistance | 137.9 kip |
| ASD allowable load | 91.93 kip |
| Applied direction factor | 1 |
| Nominal 0.707 × leg | 0.133 in |
| Effective weld length | 33.02 in |
| Effective throat area | 4.38 in² |
| Electrode classification strength | 70 ksi |
| Angle-only factor | 1 |
| Nominal weld-metal resistance | 183.87 kip |
| Governing plate thickness | 0.38 in |
| Minimum nominal leg | 0.188 in |
| Maximum edge leg | 0.313 in |
| Demand / applicable resistance | 72.5 % |
| Weld-metal load margin | 37.9 kip |
Worked example
Starting inputs
- Equal leg size
- 0.1875 in
- Weld length
- 48 in
- Angle to weld axis
- 0 °
- Length condition
- End loaded
- Demand basis
- LRFD factored
- Weld load demand
- 100 kip
- Welded edge plate
- 0.375 in
Baseline results
- Effective throat
- 0.133 in
- LRFD resistance
- 137.9 kip
- ASD allowable load
- 91.93 kip
- Applied direction factor
- 1
The 0.133 in effective throat over 33.02 in gives 4.38 in² of weld area. With direction factor 1, compare the 37.9 kip signed resistance margin with zero.
Try it. The effective length is shorter than the physical weld because the end-loaded length-to-leg ratio exceeds 100.
Calculation method
tₑ = 0.707w · LRFD = 0.75(0.60FEXX)tₑLₑk · ASD = 0.30FEXX·tₑLₑk
The angle θ is measured from the weld axis. The angle-only factor is 1 + 0.50·sin¹·⁵θ. Use 1.00 unless the selected weld condition permits the increase. Check strain compatibility for the actual weld group. AISC limits effective leg to L/4 for a short weld. For end loading, β reduces length above L/w = 100 and effective length is limited to 180w beyond L/w = 300.
The AWS screen uses the thinner piece for low-hydrogen welding and the thicker piece for the non-low-hydrogen case without qualified crack-prevention preheat. The latter case carries a single-pass condition. AISC uses the thinner piece. AWS cyclic service adds its separate minimum. The conservative edge maximum reserves 2 mm or 1/16 in at and above the corresponding quarter-inch class threshold.
The table basis fixes the inch or metric series even when you switch display units. The capacity is for one straight weld and weld metal only. Check base-metal limit states, eccentricity, fatigue and any qualified joint exceptions separately.