AWS D1.1 · AISC 360
AWS high-hydrogen case uses the thick plate
A 9 mm edge plate is joined to a 28 mm plate without taking credit for qualified crack-prevention preheat.
Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.
Inputs
Live weld sheet
Updated from inputsLeg & weld load · No common leg range · 37.5 % load utilization.
- Check the AWS single-pass condition for the selected non-low-hydrogen case.
- The selected minimum and edge allowance leave no common leg window.
Result details
| Effective throat | 3.535 mm |
|---|---|
| LRFD resistance | 95.97 kN |
| ASD allowable load | 63.98 kN |
| Applied direction factor | 1 |
| Nominal 0.707 × leg | 3.535 mm |
| Effective weld length | 125 mm |
| Effective throat area | 441.87 mm² |
| Electrode classification strength | 482.6 MPa |
| Angle-only factor | 1.217 |
| Nominal weld-metal resistance | 127.96 kN |
| Governing plate thickness | 28 mm |
| Minimum nominal leg | 8 mm |
| Maximum edge leg | 7 mm |
| Demand / applicable resistance | 37.5 % |
| Weld-metal load margin | 59.97 kN |
Worked example
Starting inputs
- Equal leg size
- 5 mm
- Weld length
- 125 mm
- Electrode strength
- E70xx
- Angle to weld axis
- 35 °
- Weld load demand
- 36 kN
- Welded edge plate
- 9 mm
- Opposite plate
- 28 mm
Baseline results
- Effective throat
- 3.535 mm
- LRFD resistance
- 95.97 kN
- ASD allowable load
- 63.98 kN
- Applied direction factor
- 1
The 3.535 mm effective throat over 125 mm gives 441.87 mm² of weld area. With direction factor 1, compare the 59.97 kN signed resistance margin with zero.
Try it. Compare the AWS thick-part minimum with the edge maximum. This detail can have no common size window.
Calculation method
tₑ = 0.707w · LRFD = 0.75(0.60FEXX)tₑLₑk · ASD = 0.30FEXX·tₑLₑk
The angle θ is measured from the weld axis. The angle-only factor is 1 + 0.50·sin¹·⁵θ. Use 1.00 unless the selected weld condition permits the increase. Check strain compatibility for the actual weld group. AISC limits effective leg to L/4 for a short weld. For end loading, β reduces length above L/w = 100 and effective length is limited to 180w beyond L/w = 300.
The AWS screen uses the thinner piece for low-hydrogen welding and the thicker piece for the non-low-hydrogen case without qualified crack-prevention preheat. The latter case carries a single-pass condition. AISC uses the thinner piece. AWS cyclic service adds its separate minimum. The conservative edge maximum reserves 2 mm or 1/16 in at and above the corresponding quarter-inch class threshold.
The table basis fixes the inch or metric series even when you switch display units. The capacity is for one straight weld and weld metal only. Check base-metal limit states, eccentricity, fatigue and any qualified joint exceptions separately.