WeldMetalLab

AWS D1.1 · AISC 360

AWS high-hydrogen case uses the thick plate

A 9 mm edge plate is joined to a 28 mm plate without taking credit for qualified crack-prevention preheat.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Weld and load
mm
mm
°
Use the increase only where the governing specification permits it.
kN
Leg limits
mm
mm

Live weld sheet

Updated from inputs
Fillet throat and forceEffective throat 3.535 mm. LRFD resistance 95.97 kN. ASD allowable load 63.98 kN. Applied direction factor 1 THROAT3.535mmLRFD95.97kNASD63.98kNLOAD FACTOR1 FILLET THROAT AND FORCE Leg 5 mmLoad angle 35 °E70xx LEG & WELD LOADFAIL
Outside screen

Leg & weld load · No common leg range · 37.5 % load utilization.

  • Check the AWS single-pass condition for the selected non-low-hydrogen case.
  • The selected minimum and edge allowance leave no common leg window.

Result details

Effective throat3.535 mm
LRFD resistance95.97 kN
ASD allowable load63.98 kN
Applied direction factor1
Nominal 0.707 × leg3.535 mm
Effective weld length125 mm
Effective throat area441.87 mm²
Electrode classification strength482.6 MPa
Angle-only factor1.217
Nominal weld-metal resistance127.96 kN
Governing plate thickness28 mm
Minimum nominal leg8 mm
Maximum edge leg7 mm
Demand / applicable resistance37.5 %
Weld-metal load margin59.97 kN

Worked example

Starting inputs

Equal leg size
5 mm
Weld length
125 mm
Electrode strength
E70xx
Angle to weld axis
35 °
Weld load demand
36 kN
Welded edge plate
9 mm
Opposite plate
28 mm

Baseline results

Effective throat
3.535 mm
LRFD resistance
95.97 kN
ASD allowable load
63.98 kN
Applied direction factor
1

The 3.535 mm effective throat over 125 mm gives 441.87 mm² of weld area. With direction factor 1, compare the 59.97 kN signed resistance margin with zero.

Try it. Compare the AWS thick-part minimum with the edge maximum. This detail can have no common size window.

Calculation method

tₑ = 0.707w · LRFD = 0.75(0.60FEXX)tₑLₑk · ASD = 0.30FEXX·tₑLₑk

The angle θ is measured from the weld axis. The angle-only factor is 1 + 0.50·sin¹·⁵θ. Use 1.00 unless the selected weld condition permits the increase. Check strain compatibility for the actual weld group. AISC limits effective leg to L/4 for a short weld. For end loading, β reduces length above L/w = 100 and effective length is limited to 180w beyond L/w = 300.

The AWS screen uses the thinner piece for low-hydrogen welding and the thicker piece for the non-low-hydrogen case without qualified crack-prevention preheat. The latter case carries a single-pass condition. AISC uses the thinner piece. AWS cyclic service adds its separate minimum. The conservative edge maximum reserves 2 mm or 1/16 in at and above the corresponding quarter-inch class threshold.