WeldMetalLab

AWS D1.1 · AISC 360

Short fillet with reduced effective throat

A short weld segment is only 21 mm long. Its specified leg is 8 mm.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Weld and load
mm
mm
°
Use the increase only where the governing specification permits it.
kN
Leg limits
mm
mm

Live weld sheet

Updated from inputs
Fillet throat and forceEffective throat 3.712 mm. LRFD resistance 21.77 kN. ASD allowable load 14.51 kN. Applied direction factor 1 THROAT3.712mmLRFD21.77kNASD14.51kNLOAD FACTOR1 FILLET THROAT AND FORCE Leg 8 mmLoad angle 0 °E90xx LEG & WELD LOADPASS
Pass · within screen

Leg & weld load · 6 mm to 16 mm · 55.1 % load utilization.

Result details

Effective throat3.712 mm
LRFD resistance21.77 kN
ASD allowable load14.51 kN
Applied direction factor1
Nominal 0.707 × leg5.656 mm
Effective weld length21 mm
Effective throat area77.95 mm²
Electrode classification strength620.5 MPa
Angle-only factor1
Nominal weld-metal resistance29.02 kN
Governing plate thickness18 mm
Minimum nominal leg6 mm
Maximum edge leg16 mm
Demand / applicable resistance55.1 %
Weld-metal load margin9.77 kN

Worked example

Starting inputs

Equal leg size
8 mm
Weld length
21 mm
Electrode strength
E90xx
Angle to weld axis
0 °
Weld load demand
12 kN
Welded edge plate
18 mm
Opposite plate
25 mm

Baseline results

Effective throat
3.712 mm
LRFD resistance
21.77 kN
ASD allowable load
14.51 kN
Applied direction factor
1

The 3.712 mm effective throat over 21 mm gives 77.95 mm² of weld area. With direction factor 1, compare the 9.77 kN signed resistance margin with zero.

Try it. The effective leg is limited to L/4 for this resistance estimate. The nominal leg remains the check against the table window.

Calculation method

tₑ = 0.707w · LRFD = 0.75(0.60FEXX)tₑLₑk · ASD = 0.30FEXX·tₑLₑk

The angle θ is measured from the weld axis. The angle-only factor is 1 + 0.50·sin¹·⁵θ. Use 1.00 unless the selected weld condition permits the increase. Check strain compatibility for the actual weld group. AISC limits effective leg to L/4 for a short weld. For end loading, β reduces length above L/w = 100 and effective length is limited to 180w beyond L/w = 300.

The AWS screen uses the thinner piece for low-hydrogen welding and the thicker piece for the non-low-hydrogen case without qualified crack-prevention preheat. The latter case carries a single-pass condition. AISC uses the thinner piece. AWS cyclic service adds its separate minimum. The conservative edge maximum reserves 2 mm or 1/16 in at and above the corresponding quarter-inch class threshold.

The table basis fixes the inch or metric series even when you switch display units. The capacity is for one straight weld and weld metal only. Check base-metal limit states, eccentricity, fatigue and any qualified joint exceptions separately.