WeldMetalLab

AWS D1.1 · AISC 360

AWS cyclic fillet minimum on a light edge

The assembly has a nominal 1/8 in fillet and is designated cyclic under the AWS detail.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Weld and load
in
in
°
Use the increase only where the governing specification permits it.
kip
Leg limits
in
in

Live weld sheet

Updated from inputs
Fillet throat and forceEffective throat 0.088 in. LRFD resistance 9.54 kip. ASD allowable load 6.36 kip. Applied direction factor 1 THROAT0.088inLRFD9.54kipASD6.36kipLOAD FACTOR1 FILLET THROAT AND FORCE Leg 0.125 inLoad angle 30 °E60xx LEG & WELD LOADFAIL
Outside screen

Leg & weld load · 0.188 in to 0.2 in · 35.3 % load utilization.

Result details

Effective throat0.088 in
LRFD resistance9.54 kip
ASD allowable load6.36 kip
Applied direction factor1
Nominal 0.707 × leg0.088 in
Effective weld length4 in
Effective throat area0.35 in²
Electrode classification strength60 ksi
Angle-only factor1.177
Nominal weld-metal resistance12.73 kip
Governing plate thickness0.2 in
Minimum nominal leg0.188 in
Maximum edge leg0.2 in
Demand / applicable resistance35.3 %
Weld-metal load margin6.17 kip

Worked example

Starting inputs

Equal leg size
0.125 in
Weld length
4 in
Electrode strength
E60xx
Angle to weld axis
30 °
Weld load demand
3.372134 kip
Welded edge plate
0.2 in
Opposite plate
0.25 in

Baseline results

Effective throat
0.088 in
LRFD resistance
9.54 kip
ASD allowable load
6.36 kip
Applied direction factor
1

The 0.088 in effective throat over 4 in gives 0.35 in² of weld area. With direction factor 1, compare the 6.17 kip signed resistance margin with zero.

Try it. Changing static service to cyclic raises the minimum nominal AWS leg for this thickness band.

Calculation method

tₑ = 0.707w · LRFD = 0.75(0.60FEXX)tₑLₑk · ASD = 0.30FEXX·tₑLₑk

The angle θ is measured from the weld axis. The angle-only factor is 1 + 0.50·sin¹·⁵θ. Use 1.00 unless the selected weld condition permits the increase. Check strain compatibility for the actual weld group. AISC limits effective leg to L/4 for a short weld. For end loading, β reduces length above L/w = 100 and effective length is limited to 180w beyond L/w = 300.

The AWS screen uses the thinner piece for low-hydrogen welding and the thicker piece for the non-low-hydrogen case without qualified crack-prevention preheat. The latter case carries a single-pass condition. AISC uses the thinner piece. AWS cyclic service adds its separate minimum. The conservative edge maximum reserves 2 mm or 1/16 in at and above the corresponding quarter-inch class threshold.

The table basis fixes the inch or metric series even when you switch display units. The capacity is for one straight weld and weld metal only. Check base-metal limit states, eccentricity, fatigue and any qualified joint exceptions separately.

References

More worked examples