WeldMetalLab

GMAW · GTAW

GMAW runtime from a rated cylinder

The supplier quotes 240 ft³ of free gas. Use that rating and the desired pressure reserve to estimate runtime.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Cylinder & torch
ft³
psig
psig
USD
CFH
Pipe purge chamber
in
in
CFH
ppm
ppm

Live weld sheet

Updated from inputs
Pipe purge cutawayTorch arc-on runtime 6.19 h. Torch gas cost per hour 12.11 USD/h. Planned purge duration 3.37 min. Model oxygen at planned time 195.6 ppm TORCH HOURS6.19hTORCH COST12.11USD/hPURGE TIME3.37minRESIDUAL O₂195.6ppm PIPE PURGE CUTAWAY Bore 6.06 inFlow 25 CFHStainless PURGE O₂ TARGETFAIL
Outside screen

Purge O₂ target · 195.6 ppm predicted vs 180 ppm target.

Result details

Torch arc-on runtime6.19 h
Torch gas cost per hour12.11 USD/h
Planned purge duration3.37 min
Model oxygen at planned time195.6 ppm
Usable cylinder free gas229.091 ft³
Dam air volume0.2006 ft³
Gas for planned purge1.4044 ft³
Mixing exchanges to target7.09
Modeled time to target3.41 min
Gas cost per planned purge0.46 USD
Whole purges per cylinder163

Worked example

Starting inputs

Cylinder capacity basis
Rated free gas
Rated free-gas volume
240 ft³
Full gauge pressure
2,200 psig
Reserve gauge pressure
100 psig
Cylinder refill cost
75 USD
Torch flow
37 CFH
Internal diameter
6.064961 in

Baseline results

Torch arc-on runtime
6.19 h
Torch gas cost per hour
12.11 USD/h
Planned purge duration
3.37 min
Model oxygen at planned time
195.6 ppm

7 exchanges of a 0.2006 ft³ chamber at 25 CFH take 3.37 min. The mixed-gas estimate at that point is 195.6 ppm against a 180 ppm target.

Try it. Raising the reserve leaves less gas for both torch time and the purge chamber.

Calculation method

t = N · V / F · O₂(N) = Cᵢ + (209,000 − Cᵢ)e⁻ᴺ

The pressure estimate expands usable gauge pressure over 101.325 kPa to ambient volume at equal temperature, using a single approximate gas Z factor. Rated free gas uses the usable fraction of gauge pressure. Torch runtime assumes continuous set flow. Start/stop gas, leaks and purge consumption shorten available torch time.

Dam volume is π·ID²·L/4. The well-mixed model assumes fresh gas at the entered oxygen level and continuous vented displacement. The entered oxygen target belongs to your WPS. Use a calibrated oxygen meter at the weld to verify purge quality before and during welding.

Keep the purge chamber vented. Shielding gases can displace breathable oxygen around the work. Follow ventilation and confined-space requirements.

References

More worked examples