GMAW · GTAW
Large-diameter pipe and wide dam spacing
A large-bore shop joint has a long purge chamber because the dams sit away from the weld preparation.
Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.
Inputs
Live weld sheet
Updated from inputsPurge O₂ target · 528 ppm predicted vs 1,000 ppm target.
Result details
| Torch arc-on runtime | 8.44 h |
|---|---|
| Torch gas cost per hour | 14.21 USD/h |
| Planned purge duration | 44.3 min |
| Model oxygen at planned time | 528 ppm |
| Usable cylinder free gas | 9.627 m³ |
| Dam air volume | 0.2584 m³ |
| Gas for planned purge | 1.5504 m³ |
| Mixing exchanges to target | 5.35 |
| Modeled time to target | 39.51 min |
| Gas cost per planned purge | 19.33 USD |
| Whole purges per cylinder | 6 |
Worked example
Starting inputs
- Cylinder water volume
- 48 L
- Gas Z factor
- 1.09
- Full gauge pressure
- 230 bar(g)
- Reserve gauge pressure
- 8.5 bar(g)
- Cylinder refill cost
- 120 USD
- Torch flow
- 19 L/min
- Internal diameter
- 598 mm
Baseline results
- Torch arc-on runtime
- 8.44 h
- Torch gas cost per hour
- 14.21 USD/h
- Planned purge duration
- 44.3 min
- Model oxygen at planned time
- 528 ppm
6 exchanges of a 0.2584 m³ chamber at 35 L/min take 44.3 min. The mixed-gas estimate at that point is 528 ppm against a 1,000 ppm target.
Try it. Halving dam spacing halves chamber volume and purge time at the same flow and exchange count.
Calculation method
t = N · V / F · O₂(N) = Cᵢ + (209,000 − Cᵢ)e⁻ᴺ
The pressure estimate expands usable gauge pressure over 101.325 kPa to ambient volume at equal temperature, using a single approximate gas Z factor. Rated free gas uses the usable fraction of gauge pressure. Torch runtime assumes continuous set flow. Start/stop gas, leaks and purge consumption shorten available torch time.
Dam volume is π·ID²·L/4. The well-mixed model assumes fresh gas at the entered oxygen level and continuous vented displacement. The entered oxygen target belongs to your WPS. Use a calibrated oxygen meter at the weld to verify purge quality before and during welding.
Keep the purge chamber vented. Shielding gases can displace breathable oxygen around the work. Follow ventilation and confined-space requirements.