WeldMetalLab

GMAW · GTAW

Titanium chamber with ten exchanges

A small titanium chamber is modeled with cleaner incoming gas and a shop target of 20 ppm.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Cylinder & torch
L
bar(g)
bar(g)
USD
L/min
Pipe purge chamber
mm
mm
L/min
ppm
ppm

Live weld sheet

Updated from inputs
Pipe purge cutawayTorch arc-on runtime 16.58 h. Torch gas cost per hour 5.13 USD/h. Planned purge duration 1.95 min. Model oxygen at planned time 11.5 ppm TORCH HOURS16.58hTORCH COST5.13USD/hPURGE TIME1.95minRESIDUAL O₂11.5ppm PIPE PURGE CUTAWAY Bore 52.5 mmFlow 5 L/minTitanium PURGE O₂ TARGETPASS
Pass · within screen

Purge O₂ target · 11.5 ppm predicted vs 20 ppm target.

Result details

Torch arc-on runtime16.58 h
Torch gas cost per hour5.13 USD/h
Planned purge duration1.95 min
Model oxygen at planned time11.5 ppm
Usable cylinder free gas8.952 m³
Dam air volume0.001 m³
Gas for planned purge0.0097 m³
Mixing exchanges to target9.36
Modeled time to target1.82 min
Gas cost per planned purge0.09 USD
Whole purges per cylinder919

Worked example

Starting inputs

Torch flow
9 L/min
Pipe material
Titanium
Internal diameter
52.5 mm
Dam-to-dam length
450 mm
Purge gas flow
5 L/min
Volume exchanges
10
Incoming gas oxygen
2 ppm

Baseline results

Torch arc-on runtime
16.58 h
Torch gas cost per hour
5.13 USD/h
Planned purge duration
1.95 min
Model oxygen at planned time
11.5 ppm

10 exchanges of a 0.001 m³ chamber at 5 L/min take 1.95 min. The mixed-gas estimate at that point is 11.5 ppm against a 20 ppm target.

Try it. Check the oxygen margin at ten exchanges and verify the actual reading under the planned vent and joint setup.

Calculation method

t = N · V / F · O₂(N) = Cᵢ + (209,000 − Cᵢ)e⁻ᴺ

The pressure estimate expands usable gauge pressure over 101.325 kPa to ambient volume at equal temperature, using a single approximate gas Z factor. Rated free gas uses the usable fraction of gauge pressure. Torch runtime assumes continuous set flow. Start/stop gas, leaks and purge consumption shorten available torch time.

Dam volume is π·ID²·L/4. The well-mixed model assumes fresh gas at the entered oxygen level and continuous vented displacement. The entered oxygen target belongs to your WPS. Use a calibrated oxygen meter at the weld to verify purge quality before and during welding.

Keep the purge chamber vented. Shielding gases can displace breathable oxygen around the work. Follow ventilation and confined-space requirements.