GMAW · GTAW
GMAW runtime from a rated cylinder
The supplier quotes 240 ft³ of free gas. Use that rating and the desired pressure reserve to estimate runtime.
Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.
Inputs
Live weld sheet
Updated from inputsPurge O₂ target · 195.6 ppm predicted vs 180 ppm target.
Result details
| Torch arc-on runtime | 6.19 h |
|---|---|
| Torch gas cost per hour | 12.11 USD/h |
| Planned purge duration | 3.37 min |
| Model oxygen at planned time | 195.6 ppm |
| Usable cylinder free gas | 229.091 ft³ |
| Dam air volume | 0.2006 ft³ |
| Gas for planned purge | 1.4044 ft³ |
| Mixing exchanges to target | 7.09 |
| Modeled time to target | 3.41 min |
| Gas cost per planned purge | 0.46 USD |
| Whole purges per cylinder | 163 |
Worked example
Starting inputs
- Cylinder capacity basis
- Rated free gas
- Rated free-gas volume
- 240 ft³
- Full gauge pressure
- 2,200 psig
- Reserve gauge pressure
- 100 psig
- Cylinder refill cost
- 75 USD
- Torch flow
- 37 CFH
- Internal diameter
- 6.064961 in
Baseline results
- Torch arc-on runtime
- 6.19 h
- Torch gas cost per hour
- 12.11 USD/h
- Planned purge duration
- 3.37 min
- Model oxygen at planned time
- 195.6 ppm
7 exchanges of a 0.2006 ft³ chamber at 25 CFH take 3.37 min. The mixed-gas estimate at that point is 195.6 ppm against a 180 ppm target.
Try it. Raising the reserve leaves less gas for both torch time and the purge chamber.
Calculation method
t = N · V / F · O₂(N) = Cᵢ + (209,000 − Cᵢ)e⁻ᴺ
The pressure estimate expands usable gauge pressure over 101.325 kPa to ambient volume at equal temperature, using a single approximate gas Z factor. Rated free gas uses the usable fraction of gauge pressure. Torch runtime assumes continuous set flow. Start/stop gas, leaks and purge consumption shorten available torch time.
Dam volume is π·ID²·L/4. The well-mixed model assumes fresh gas at the entered oxygen level and continuous vented displacement. The entered oxygen target belongs to your WPS. Use a calibrated oxygen meter at the weld to verify purge quality before and during welding.
Keep the purge chamber vented. Shielding gases can displace breathable oxygen around the work. Follow ventilation and confined-space requirements.