WeldMetalLab

Fit-up · Restraint

Balanced fillet sequence on a built-up beam

A balanced sequence is being considered for a continuous T-joint on a 12 ft beam.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Seam & fit-up
in
in²
kJ/in
%
Member & restraint
ft
in
ksi
in⁴
%
in

Live weld sheet

Updated from inputs
Free distortion and bowFree transverse shrinkage 0.027 in. Free angular rotation 0.42 °. Bow under entered restraint 0.091 in. Opposite trial counter-camber -0.091 in SHRINKAGE0.027inROTATION0.42°HELD BOW0.091inCOUNTER-SET-0.091in FREE DISTORTION AND BOW End sectionSide elevationSpan 12 ftSet -0.091 inFillet BOW TOLERANCEPASS
Pass · within screen

Bow tolerance · 0.091 in magnitude vs 0.125 in tolerance.

Result details

Free transverse shrinkage0.027 in
Free angular rotation0.42 °
Bow under entered restraint0.091 in
Opposite trial counter-camber-0.091 in
Longitudinal tendon force117.43 kip
Signed eccentric moment8.476 kip·ft
Free signed bow0.151 in
Held transverse shrinkage0.016 in
Held angular rotation0.25 °
Remaining bow tolerance0.034 in

Worked example

Starting inputs

Joint family
Fillet weld
Plate or flange thickness
0.5 in
Deposited weld area
0.1116 in²
Net heat per pass
21.59 kJ/in
Effective passes
3
Angular balance
80 %
Member span
12 ft

Baseline results

Free transverse shrinkage
0.027 in
Free angular rotation
0.42 °
Bow under entered restraint
0.091 in
Opposite trial counter-camber
-0.091 in

A 117.43 kip tendon acting at 0.87 in gives a signed moment of 8.476 kip·ft. Free bow is 0.151 in before applying the entered restraint reduction.

Try it. Angular balance reduces modeled rotation. Moving the net tendon closer to the centroid reduces longitudinal bow.

Calculation method

Δₜ ≈ k(C·A/t + Cg·g) · F ≈ 0.335EαQ/(ρc) · δ ≈ (F·e)L²/(8EI)

The free steel butt fit-up estimate uses C = 0.20 and Cg = 0.05. The fillet approximation uses C = 0.12 and no gap term. Apply a shop calibration multiplier to these estimates and to the angular scale αQ/(ρc·t²). Angular balance reduces rotation. The simple thermal estimate uses the entered effective pass count and typical steel heat capacity and expansion.

The tendon force acts at the signed weld offset to produce an approximately constant bending moment. Bow uses small-deflection constant curvature over the span. The restraint percentage is a sensitivity input applied to displacement only. Released parts may spring back, and strong restraint can raise residual stress and cracking risk.

The counter-camber is the signed opposite of the modeled held bow. Treat it as a trial adjustment. Confirm geometry and distortion on a representative weld, especially with thin plates or highly eccentric seams.

References

More worked examples