Worked example
20-Gallon Nano Reef Magnesium Rise of 50 ppm Over Two Days
This nano reef holds 20 net gallons. The magnesium target is 1,300 ppm from a verified 1,250 ppm reading. Plan two days at a maximum 25 ppm/day and four pulses per channel.
See the worked calculationInputs
Results
Edit inputs20-Gallon Nano Reef Magnesium Rise of 50 ppm Over Two Days
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/20-gallon-nano-reef-magnesium-50-ppm-over-two-days/
- Magnesium first-day pulse
- 21.99 mL
- Alkalinity first-day pulse
- 0 mL
- Calcium first-day pulse
- 0 mL
Calculation details
- Total NaHCO₃ to target
- 0 g
- Total CaCl₂·2H₂O to target
- 0 g
- Total MgCl₂·6H₂O to target
- 31.664 g
- Total MgSO₄·7H₂O to target
- 0 g
- Alkalinity maintenance pulse
- 0 mL
- Spacing between pulses on one channel
- 6 hr
| Channel | Total to target | Observed loss per day | First-day correction | Correction days | Maintenance per day | Maintenance per pulse |
|---|---|---|---|---|---|---|
| Alkalinity | 0 mL | 0 dKH | 0 mL | 0 | 0 mL | 0 mL |
| Calcium | 0 mL | 0 ppm | 0 mL | 0 | 0 mL | 0 mL |
| Magnesium | 175.91 mL | 0 ppm | 87.95 mL | 2 | 0 mL | 0 mL |
- Correction and maintenance are separate plans. Retest before combining them and stagger alkalinity and calcium pulses.
Input measurements
- Net system water
- 20 US gal
- Days between tests
- 2 days
- Pulses per channel per day
- 4
- Alkalinity salt
- Sodium bicarbonate · NaHCO₃
- Current alkalinity
- 8 dKH
- Target alkalinity
- 8 dKH
- Earlier alkalinity test
- 8 dKH
- Alkalinity stock strength
- 78.5 g/L
- Alkalinity daily cap
- 1 dKH
- Calcium chloride form
- Dihydrate · CaCl₂·2H₂O
- Current calcium
- 420 ppm
- Target calcium
- 420 ppm
- Earlier calcium test
- 420 ppm
- Calcium stock strength
- 132 g/L
- Calcium daily cap
- 15 ppm
- Elemental magnesium from chloride
- 100 %
- Current magnesium
- 1,250 ppm
- Target magnesium
- 1,300 ppm
- Earlier magnesium test
- 1,250 ppm
- Magnesium stock strength
- 180 g/L
- Magnesium daily cap
- 25 ppm
Recheck alkalinity, calcium, magnesium and salinity with suitable test kits. Follow the product label and adjust gradually for your livestock. Calibrate each pump head and separate alkalinity and calcium additions.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Convert the magnesium gap to reagent mass
1,300 − 1,250 = 50 ppm; × 75.708 L × 0.00836 g/L per ppm → 31.664 g
Allocate 100% of elemental magnesium to MgCl₂·6H₂O and 0% to MgSO₄·7H₂O. That gives 31.664 g chloride salt and 0 g sulfate salt for this correction.
Convert the dry equivalent to stock volume
31.664 g ÷ 180 g/L × 1,000 = 175.91 mL total to target
This uses the strength of the finished solution. A solution with a different concentration requires a different liquid volume.
Cap and split the first day
min(50, 25) = 25 ppm; 87.95 mL ÷ 4 = 21.99 mL per pulse
The correction takes at least 2 modeled days. Test before each continuation and avoid combining the full correction with a maintenance schedule.
Use the measured loss for maintenance
(1,250 − 1,250) ÷ 2 = 0 ppm/day → 0 mL/day → 0 mL/pulse
A 4-pulse plan spaces one channel’s events 6 hours apart. Verify a no-dose interval and stagger dosing channels.
Frequently asked questions
Why can a nano reef need a lower per-pulse amount than the calculator shows?
Individual fish and corals, pump precision and the dosing location can justify smaller additions. Select a lower daily cap and verify the results with a test kit.
Can I set the first-day magnesium dose to repeat indefinitely?
Use it only for the staged correction. Retest before each day and compute maintenance separately from measured consumption.