Worked example

20-Gallon Nano Reef Magnesium Rise of 50 ppm Over Two Days

This nano reef holds 20 net gallons. The magnesium target is 1,300 ppm from a verified 1,250 ppm reading. Plan two days at a maximum 25 ppm/day and four pulses per channel.

See the worked calculation

Inputs

View results
System and observations
US gal

Use actual display and sump water after displacement.

days

For maintenance, measure with no dosing or water changes between tests.

Stagger alkalinity and calcium delivery.

Alkalinity
dKH
dKH
dKH

Use a test from before the no-dose observation period.

g/L

Use the concentration of the selected pure salt in the finished stock.

dKH

Use a lower limit if your livestock or product label calls for it.

Calcium
ppm
ppm
ppm

Use a test from before the no-dose observation period.

g/L

Match the hydration form on the label.

ppm

Use a lower limit if your livestock or product label calls for it.

Magnesium
%

The balance comes from magnesium sulfate. This is an elemental share, not the share by salt weight.

ppm
ppm
ppm

Use a test from before the no-dose observation period.

g/L

Total grams of both hydrated magnesium salts per liter of finished stock.

ppm

Use a lower limit if your livestock or product label calls for it.

Magnesium first-day pulse
21.99 mL
Alkalinity first-day pulse
0 mL
Calcium first-day pulse
0 mL
Corrections and daily raise limitsEach scale starts at the current reading. The teal bar is the first-day correction. The coral marker is the full upward target. Current readingFirst day / targetAlkalinity8 dKH0 / 0 dKHCalcium420 ppm0 / 0 ppmMagnesium1,250 ppm25 / 50 ppmFirst-day raiseFull upward target
Corrections & daily raise limits

Calculation details

Total NaHCO₃ to target
0 g
Total CaCl₂·2H₂O to target
0 g
Total MgCl₂·6H₂O to target
31.664 g
Total MgSO₄·7H₂O to target
0 g
Alkalinity maintenance pulse
0 mL
Spacing between pulses on one channel
6 hr
Dosing schedule by channel
ChannelTotal to targetObserved loss per dayFirst-day correctionCorrection daysMaintenance per dayMaintenance per pulse
Alkalinity0 mL0 dKH0 mL00 mL0 mL
Calcium0 mL0 ppm0 mL00 mL0 mL
Magnesium175.91 mL0 ppm87.95 mL20 mL0 mL
  • Correction and maintenance are separate plans. Retest before combining them and stagger alkalinity and calcium pulses.

Input measurements

Net system water
20 US gal
Days between tests
2 days
Pulses per channel per day
4
Alkalinity salt
Sodium bicarbonate · NaHCO₃
Current alkalinity
8 dKH
Target alkalinity
8 dKH
Earlier alkalinity test
8 dKH
Alkalinity stock strength
78.5 g/L
Alkalinity daily cap
1 dKH
Calcium chloride form
Dihydrate · CaCl₂·2H₂O
Current calcium
420 ppm
Target calcium
420 ppm
Earlier calcium test
420 ppm
Calcium stock strength
132 g/L
Calcium daily cap
15 ppm
Elemental magnesium from chloride
100 %
Current magnesium
1,250 ppm
Target magnesium
1,300 ppm
Earlier magnesium test
1,250 ppm
Magnesium stock strength
180 g/L
Magnesium daily cap
25 ppm

Recheck alkalinity, calcium, magnesium and salinity with suitable test kits. Follow the product label and adjust gradually for your livestock. Calibrate each pump head and separate alkalinity and calcium additions.

Worked calculation

These numbers use the original example measurements. The calculator above updates as you edit.

  1. Convert the magnesium gap to reagent mass

    1,300 − 1,250 = 50 ppm; × 75.708 L × 0.00836 g/L per ppm → 31.664 g

    Allocate 100% of elemental magnesium to MgCl₂·6H₂O and 0% to MgSO₄·7H₂O. That gives 31.664 g chloride salt and 0 g sulfate salt for this correction.

  2. Convert the dry equivalent to stock volume

    31.664 g ÷ 180 g/L × 1,000 = 175.91 mL total to target

    This uses the strength of the finished solution. A solution with a different concentration requires a different liquid volume.

  3. Cap and split the first day

    min(50, 25) = 25 ppm; 87.95 mL ÷ 4 = 21.99 mL per pulse

    The correction takes at least 2 modeled days. Test before each continuation and avoid combining the full correction with a maintenance schedule.

  4. Use the measured loss for maintenance

    (1,250 − 1,250) ÷ 2 = 0 ppm/day → 0 mL/day → 0 mL/pulse

    A 4-pulse plan spaces one channel’s events 6 hours apart. Verify a no-dose interval and stagger dosing channels.

Frequently asked questions

Why can a nano reef need a lower per-pulse amount than the calculator shows?

Individual fish and corals, pump precision and the dosing location can justify smaller additions. Select a lower daily cap and verify the results with a test kit.

Can I set the first-day magnesium dose to repeat indefinitely?

Use it only for the staged correction. Retest before each day and compute maintenance separately from measured consumption.