Worked example
65-Gallon Reef Magnesium Chloride and Sulfate Dose
Magnesium is 1,270 ppm in 65 net gallons and the target is 1,320 ppm. In this preset, magnesium chloride provides 80% of the elemental increase and magnesium sulfate supplies the balance.
See the worked calculationInputs
Results
Edit inputs65-Gallon Reef Magnesium Chloride and Sulfate Dose
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/65-gallon-reef-magnesium-chloride-sulfate-dose/
- Total MgCl₂·6H₂O to target
- 82.326 g
- Alkalinity first-day pulse
- 0 mL
- Calcium first-day pulse
- 0 mL
Calculation details
- Magnesium first-day pulse
- 74.5 mL
- Total NaHCO₃ to target
- 0 g
- Total CaCl₂·2H₂O to target
- 0 g
- Total MgSO₄·7H₂O to target
- 24.951 g
- Alkalinity maintenance pulse
- 0 mL
- Spacing between pulses on one channel
- 6 hr
| Channel | Total to target | Observed loss per day | First-day correction | Correction days | Maintenance per day | Maintenance per pulse |
|---|---|---|---|---|---|---|
| Alkalinity | 0 mL | 0 dKH | 0 mL | 0 | 0 mL | 0 mL |
| Calcium | 0 mL | 0 ppm | 0 mL | 0 | 0 mL | 0 mL |
| Magnesium | 595.98 mL | 0 ppm | 297.99 mL | 2 | 0 mL | 0 mL |
- Correction and maintenance are separate plans. Retest before combining them and stagger alkalinity and calcium pulses.
Input measurements
- Net system water
- 65 US gal
- Days between tests
- 2 days
- Pulses per channel per day
- 4
- Alkalinity salt
- Sodium bicarbonate · NaHCO₃
- Current alkalinity
- 8 dKH
- Target alkalinity
- 8 dKH
- Earlier alkalinity test
- 8 dKH
- Alkalinity stock strength
- 78.5 g/L
- Alkalinity daily cap
- 1 dKH
- Calcium chloride form
- Dihydrate · CaCl₂·2H₂O
- Current calcium
- 420 ppm
- Target calcium
- 420 ppm
- Earlier calcium test
- 420 ppm
- Calcium stock strength
- 132 g/L
- Calcium daily cap
- 15 ppm
- Elemental magnesium from chloride
- 80 %
- Current magnesium
- 1,270 ppm
- Target magnesium
- 1,320 ppm
- Earlier magnesium test
- 1,270 ppm
- Magnesium stock strength
- 180 g/L
- Magnesium daily cap
- 25 ppm
Recheck alkalinity, calcium, magnesium and salinity with suitable test kits. Follow the product label and adjust gradually for your livestock. Calibrate each pump head and separate alkalinity and calcium additions.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Convert the magnesium gap to reagent mass
1,320 − 1,270 = 50 ppm; × 246.052 L × 0.00872 g/L per ppm → 107.277 g
Allocate 80% of elemental magnesium to MgCl₂·6H₂O and 20% to MgSO₄·7H₂O. That gives 82.326 g chloride salt and 24.951 g sulfate salt for this correction.
Convert the dry equivalent to stock volume
107.277 g ÷ 180 g/L × 1,000 = 595.98 mL total to target
This uses the strength of the finished solution. A solution with a different concentration requires a different liquid volume.
Cap and split the first day
min(50, 25) = 25 ppm; 297.99 mL ÷ 4 = 74.5 mL per pulse
The correction takes at least 2 modeled days. Test before each continuation and avoid combining the full correction with a maintenance schedule.
Use the measured loss for maintenance
(1,270 − 1,270) ÷ 2 = 0 ppm/day → 0 mL/day → 0 mL/pulse
A 4-pulse plan spaces one channel’s events 6 hours apart. Verify a no-dose interval and stagger dosing channels.
Frequently asked questions
Does an 80/20 magnesium blend mean 80% of the dry salt by weight?
No. It divides the elemental magnesium. Different hydrated salts contain different magnesium mass fractions, which changes how much of each powder to weigh.
Could I use magnesium sulfate for the entire 65-gallon adjustment?
The tool can show the corresponding mass, but repeated additions from one salt can shift the chloride-to-sulfate balance. Follow a formulation designed for the system.