Worked example
75-Gallon Reef Daily Alkalinity Consumption & Auto-Doser Schedule
In a 75-gallon system, alkalinity drops from 8.7 to 7.8 dKH in three days without dosing or water changes. Separate daily replacement from a one-time rise to target.
See the worked calculationInputs
Results
Edit inputs75-Gallon Reef Daily Alkalinity Consumption & Auto-Doser Schedule
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/75-gallon-reef-daily-alkalinity-consumption-auto-doser/
- Alkalinity maintenance pulse
- 5.43 mL
- Alkalinity first-day pulse
- 7.23 mL
- Calcium first-day pulse
- 0 mL
Calculation details
- Magnesium first-day pulse
- 0 mL
- Total NaHCO₃ to target
- 3.407 g
- Total CaCl₂·2H₂O to target
- 0 g
- Total MgCl₂·6H₂O to target
- 0 g
- Total MgSO₄·7H₂O to target
- 0 g
- Spacing between pulses on one channel
- 4 hr
| Channel | Total to target | Observed loss per day | First-day correction | Correction days | Maintenance per day | Maintenance per pulse |
|---|---|---|---|---|---|---|
| Alkalinity | 43.4 mL | 0.3 dKH | 43.4 mL | 1 | 32.55 mL | 5.43 mL |
| Calcium | 0 mL | 0 ppm | 0 mL | 0 | 0 mL | 0 mL |
| Magnesium | 0 mL | 0 ppm | 0 mL | 0 | 0 mL | 0 mL |
- Correction and maintenance are separate plans. Retest before combining them and stagger alkalinity and calcium pulses.
Input measurements
- Net system water
- 75 US gal
- Days between tests
- 3 days
- Pulses per channel per day
- 6
- Alkalinity salt
- Sodium bicarbonate · NaHCO₃
- Current alkalinity
- 7.8 dKH
- Target alkalinity
- 8.2 dKH
- Earlier alkalinity test
- 8.7 dKH
- Alkalinity stock strength
- 78.5 g/L
- Alkalinity daily cap
- 1 dKH
- Calcium chloride form
- Dihydrate · CaCl₂·2H₂O
- Current calcium
- 420 ppm
- Target calcium
- 420 ppm
- Earlier calcium test
- 420 ppm
- Calcium stock strength
- 132 g/L
- Calcium daily cap
- 15 ppm
- Elemental magnesium from chloride
- 80 %
- Current magnesium
- 1,320 ppm
- Target magnesium
- 1,320 ppm
- Earlier magnesium test
- 1,320 ppm
- Magnesium stock strength
- 180 g/L
- Magnesium daily cap
- 25 ppm
Recheck alkalinity, calcium, magnesium and salinity with suitable test kits. Follow the product label and adjust gradually for your livestock. Calibrate each pump head and separate alkalinity and calcium additions.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Use the measured loss for maintenance
(8.7 − 7.8) ÷ 3 = 0.3 dKH/day → 32.55 mL/day → 5.43 mL/pulse
A 6-pulse plan spaces one channel’s events 4 hours apart. Verify a no-dose interval and stagger dosing channels.
Convert the alkalinity gap to reagent mass
8.2 − 7.8 = 0.4 dKH; × 283.906 L × 0.03 g/L per dKH → 3.407 g
For NaHCO₃, divide 84.0066 g/mol by 2,800 × 1 to get grams per liter per dKH.
Convert the dry equivalent to stock volume
3.407 g ÷ 78.5 g/L × 1,000 = 43.4 mL total to target
This uses the strength of the finished solution. A solution with a different concentration requires a different liquid volume.
Cap and split the first day
min(0.4, 1) = 0.4 dKH; 43.4 mL ÷ 6 = 7.23 mL per pulse
The correction takes at least 1 modeled day. Test before each continuation and avoid combining the full correction with a maintenance schedule.
Frequently asked questions
What happens to this maintenance schedule if I shorten the observation window?
The same measured drop over fewer days implies more daily consumption. Very short windows can turn ordinary test noise into a large daily estimate.
When should I retune the six-pulse schedule?
Retest at the same time of day and check for drift across several readings. Change the total when the trend is repeatable or livestock demand changes.