Worked example

53 mS/cm Conductivity to Reef Salinity at 25 °C

An aquarium conductivity probe reads 53 mS/cm at 25 °C. Use the surface-pressure PSS-78 conversion and compare the result with the reef’s separate refractometer.

See the worked calculation

Inputs

View results
Tank reading
°C
mS/cm

If the meter shows conductivity normalized to 25 °C, use 25 °C.

New batch
L
ppt

Use 0 for freshwater in the dilution model.

g/L

Confirm the amount of your brand needed for a finished liter at 35 ppt.

g

Weigh a level 236.6 mL cup of your dry mix.

Water change
L
%
ppt
Tank practical salinity
34.95 PSS-78
Dry salt for this batch
2,876.9 g
Salinity after the water change
34.96 ppt
Salinity as replacement fraction increasesTank starts at 34.95. A 20 percent change ends at 34.96 ppt. Approximate salinity · ppt0%25%50%75%100%34.43535.5System water replaced● Selected: 34.96 ppt
Water-change salinity curve

Calculation details

Same-temperature specific gravity
1.02633
Conductivity at sample temperature
53 mS/cm
Seawater density
1,023.3 kg/m³
Salt mix by volume
9.92 US cups
Volume for selected change
68.1 L
Batch salinity needed at selected change
35.21 ppt
Volume needed with this batch
340.7 L
  • Check the mix label and calibrate the instrument against the reference convention it uses.

Input measurements

Reading to convert
Conductivity (not normalized)
Sample temperature
25 °C
Conductivity at sample temperature
53 mS/cm
Finished batch volume
75.70824 L
Replacement batch salinity
35 ppt
Label dose at 35 ppt
38 g/L
Weighed grams per US cup
290 g
Net system water
340.68706 L
System volume replaced
20 %
Desired system salinity
35 ppt

Use a calibrated refractometer or conductivity meter, check temperature and salinity before adding new water, and make gradual changes appropriate for your livestock. Replace ordinary evaporation with unsalted freshwater.

Worked calculation

These numbers use the original example measurements. The calculator above updates as you edit.

  1. Convert the sample at its temperature

    53 mS/cm at 25 °C → 34.95 practical salinity, SG 1.02633, 53 mS/cm

    PSS-78 relates conductivity to salinity. EOS-80 gives the density ratio to pure water at the same temperature.

  2. Scale the dry salt to the finished batch

    75.708 L × 38 g/L × (35 ÷ 35) = 2,876.9 g; ÷ 290 g/cup = 9.92 US cups

    Use the recorded label dose and a weighed level cup for this blend.

  3. Take the weighted average after the change

    (1 − 0.2) × 34.95 + 0.2 × 35 = 34.96 ppt

    The selected fraction replaces 68.14 L of the net system.

  4. Solve for the desired salinity

    [35 − (1 − 0.2) × 34.95] ÷ 0.2 = 35.21 ppt in the batch

    Holding the batch salinity fixed instead gives 340.69 L of total modeled replacement.

Frequently asked questions

How do I enter a reading of 53,000 µS/cm?

Divide microsiemens per centimeter by 1,000 to enter 53 mS/cm. Confirm the unit on the meter before comparing values.

Can a two-point conductivity calibration improve checks near 53 mS/cm?

Follow the meter instructions and use a standard appropriate to the marine range. Rinse the probe and allow the temperature and reading to settle.