Worked example

Convert 1.020 Specific Gravity to ppt at 77 °F

Your meter shows a specific gravity of 1.020 at 77 °F. This example assumes it reports the density ratio at that same temperature. Check before applying the result to a hydrometer with a different reference.

See the worked calculation

Inputs

View results
Tank reading
°F

Use density ratio relative to pure water at the same sample temperature.

New batch
US gal
ppt

Use 0 for freshwater in the dilution model.

g/L

Confirm the amount of your brand needed for a finished liter at 35 ppt.

g

Weigh a level 236.6 mL cup of your dry mix.

Water change
US gal
%
ppt
Tank practical salinity
26.57 PSS-78
Dry salt for this batch
2,876.9 g
Salinity after the water change
27.42 ppt
Salinity as replacement fraction increasesTank starts at 26.57. A 10 percent change ends at 27.42 ppt. Approximate salinity · ppt0%25%50%75%100%26.130.835.5System water replaced● Selected: 27.42 ppt
Water-change salinity curve

Calculation details

Same-temperature specific gravity
1.02
Conductivity at sample temperature
41.48 mS/cm
Seawater density
1,016.99 kg/m³
Salt mix by volume
9.92 US cups
Volume for selected change
9 US gal
Batch salinity needed at selected change
—
Volume needed with this batch
90 US gal
  • The selected change size cannot reach the desired target within the modeled 0–42 ppt batch range.
  • Check the mix label and calibrate the instrument against the reference convention it uses.

Input measurements

Reading to convert
Specific gravity (same temperature)
Sample temperature
77 °F
Specific gravity
1.02
Finished batch volume
20 US gal
Replacement batch salinity
35 ppt
Label dose at 35 ppt
38 g/L
Weighed grams per US cup
290 g
Net system water
90 US gal
System volume replaced
10 %
Desired system salinity
35 ppt

Use a calibrated refractometer or conductivity meter, check temperature and salinity before adding new water, and make gradual changes appropriate for your livestock. Replace ordinary evaporation with unsalted freshwater.

Worked calculation

These numbers use the original example measurements. The calculator above updates as you edit.

  1. Convert the sample at its temperature

    SG 1.02 at 77 °F → 26.57 practical salinity, SG 1.02, 41.48 mS/cm

    PSS-78 relates conductivity to salinity. EOS-80 gives the density ratio to pure water at the same temperature.

  2. Scale the dry salt to the finished batch

    75.708 L × 38 g/L × (35 ÷ 35) = 2,876.9 g; ÷ 290 g/cup = 9.92 US cups

    Use the recorded label dose and a weighed level cup for this blend.

  3. Take the weighted average after the change

    (1 − 0.1) × 26.57 + 0.1 × 35 = 27.42 ppt

    The selected fraction replaces 9 US gal of the net system.

  4. Solve for the desired salinity

    [35 − (1 − 0.1) × 26.57] ÷ 0.1 = 110.84 ppt in the batch

    Holding the batch salinity fixed instead gives 90 US gal of total modeled replacement.

Frequently asked questions

Should I convert a 1.020 hydrometer reading with water or air temperature?

Use the actual water sample temperature and the instrument’s reference convention. Ambient air temperature can differ from water temperature.

Does automatic temperature compensation fix a miscalibrated 1.020 reading?

Temperature compensation addresses a temperature effect, not a calibration offset or the use of the wrong scale. Check the instrument against a relevant standard.