Reef chemistry

Saltwater Salinity, Specific Gravity & Salt Mixing Calculator

Convert specific gravity, salinity and conductivity by temperature, then estimate marine salt by weight or cup and model a reef water change.

Inputs

View results
Tank reading
°F
PSS-78
New batch
US gal
ppt

Use 0 for freshwater in the dilution model.

g/L

Confirm the amount of your brand needed for a finished liter at 35 ppt.

g

Weigh a level 236.6 mL cup of your dry mix.

Water change
US gal
%
ppt
Dry salt for this batch
2,876.9 g
Tank practical salinity
34 PSS-78
Salinity after the water change
34.2 ppt
Salinity as replacement fraction increasesTank starts at 34. A 20 percent change ends at 34.2 ppt. Approximate salinity · ppt0%25%50%75%100%33.534.535.5System water replaced● Selected: 34.2 ppt
Water-change salinity curve

Calculation details

Same-temperature specific gravity
1.02561
Conductivity at sample temperature
51.72 mS/cm
Seawater density
1,022.59 kg/m³
Salt mix by volume
9.92 US cups
Volume for selected change
18 US gal
Batch salinity needed at selected change
39 ppt
Volume needed with this batch
90 US gal
  • Check the mix label and calibrate the instrument against the reference convention it uses.

Input measurements

Reading to convert
Practical salinity (PSS-78)
Sample temperature
77 °F
Practical salinity
34 PSS-78
Finished batch volume
20 US gal
Replacement batch salinity
35 ppt
Label dose at 35 ppt
38 g/L
Weighed grams per US cup
290 g
Net system water
90 US gal
System volume replaced
20 %
Desired system salinity
35 ppt

Use a calibrated refractometer or conductivity meter, check temperature and salinity before adding new water, and make gradual changes appropriate for your livestock. Replace ordinary evaporation with unsalted freshwater.

How the calculation works

Conductivity uses the PSS-78 surface-pressure polynomial. Specific gravity uses the EOS-80 density ratio, seawater divided by pure water at the same temperature. Some hydrometers use a different reference temperature. Practical Salinity is unitless and serves as a close numerical proxy for typical aquarium ppt.

The salt estimate multiplies finished liters by the label’s grams per liter at 35 ppt and scales linearly to the batch target. Cup weight varies with the mix and packing, so weigh the mix first and measure the final batch.

The water-change model takes the volume-weighted mean of the tank and replacement salinities. It assumes comparable densities and complete mixing. Use it to plan small changes and verify with a calibrated instrument.

References

Frequently asked questions

Does 35 practical salinity always read 1.026 on a hydrometer?

The reading depends on sample temperature and the instrument’s reference convention. At 25 °C, the same-temperature density ratio is about 1.0264. Check the calibration specification on your device.

Can I use a measuring cup to prepare an entire saltwater batch?

You can estimate by cup after weighing a level cup of your mix. Use a scale for repeatability and verify final salinity after the salt dissolves.