Reef chemistry
Saltwater Salinity, Specific Gravity & Salt Mixing Calculator
Convert specific gravity, salinity and conductivity by temperature, then estimate marine salt by weight or cup and model a reef water change.
Inputs
Results
Edit inputsSaltwater Salinity, Specific Gravity & Salt Mixing Calculator
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/saltwater-salinity-sg-ppt-water-change-mixing-calculator/
- Dry salt for this batch
- 2,876.9 g
- Tank practical salinity
- 34 PSS-78
- Salinity after the water change
- 34.2 ppt
Calculation details
- Same-temperature specific gravity
- 1.02561
- Conductivity at sample temperature
- 51.72 mS/cm
- Seawater density
- 1,022.59 kg/m³
- Salt mix by volume
- 9.92 US cups
- Volume for selected change
- 18 US gal
- Batch salinity needed at selected change
- 39 ppt
- Volume needed with this batch
- 90 US gal
- Check the mix label and calibrate the instrument against the reference convention it uses.
Input measurements
- Reading to convert
- Practical salinity (PSS-78)
- Sample temperature
- 77 °F
- Practical salinity
- 34 PSS-78
- Finished batch volume
- 20 US gal
- Replacement batch salinity
- 35 ppt
- Label dose at 35 ppt
- 38 g/L
- Weighed grams per US cup
- 290 g
- Net system water
- 90 US gal
- System volume replaced
- 20 %
- Desired system salinity
- 35 ppt
Use a calibrated refractometer or conductivity meter, check temperature and salinity before adding new water, and make gradual changes appropriate for your livestock. Replace ordinary evaporation with unsalted freshwater.
How the calculation works
Conductivity uses the PSS-78 surface-pressure polynomial. Specific gravity uses the EOS-80 density ratio, seawater divided by pure water at the same temperature. Some hydrometers use a different reference temperature. Practical Salinity is unitless and serves as a close numerical proxy for typical aquarium ppt.
The salt estimate multiplies finished liters by the label’s grams per liter at 35 ppt and scales linearly to the batch target. Cup weight varies with the mix and packing, so weigh the mix first and measure the final batch.
The water-change model takes the volume-weighted mean of the tank and replacement salinities. It assumes comparable densities and complete mixing. Use it to plan small changes and verify with a calibrated instrument.
References
Frequently asked questions
Does 35 practical salinity always read 1.026 on a hydrometer?
The reading depends on sample temperature and the instrument’s reference convention. At 25 °C, the same-temperature density ratio is about 1.0264. Check the calibration specification on your device.
Can I use a measuring cup to prepare an entire saltwater batch?
You can estimate by cup after weighing a level cup of your mix. Use a scale for repeatability and verify final salinity after the salt dissolves.