Absorptive aggregate trial

Compare total and effective binder in a trial blend with higher effective aggregate SG.

Design readout

Air voids
4.06
%
VMA
12.68
%
VFA
68.01
%
Eff. binder
3.74
%

Compacted mix phase blocks

Compacted mix phase blocksVOLUME FRACTIONSNMAS ¾ inAIR4.1%EFF. BINDER8.6%BULK AGGREGATE87.3%VMA12.68%VFA68.01%DUST RATIO1.164
VMA contains air plus effective binder. Absorbed binder lies within the bulk aggregate volume.

Review VMA

VMA is 12.681%. Screening limit is 13% minimum.

Calculation ledger
Aggregate by mix mass
94.3%
Effective aggregate SG
2.7212
Absorbed binder by aggregate mass
2.082%
Dust-to-binder ratio
1.164
Minimum design VMA
13%
Lower design VFA limit
65%
Upper design VFA limit
75%

Inputs

Changes update results

Binder and aggregate
%
%
Measured mix and design class

Work through this example

  1. Use Rice SG and binder fractions to calculate effective aggregate SG.
  2. Compute air and mineral void volumes from the compacted specimen.
  3. Correct binder for aggregate absorption and compare the volumetric screen.

Read Pᵦₐ from the ledger and compare the total binder to effective binder.

The screen uses the FHWA Superpave workbook limits and a ±0.1 percentage-point display band about 4.0% design air voids. Verify current agency mix specifications, gyrations, moisture susceptibility and any gradation exceptions.

Read the equations and sources