VMA contains air plus effective binder. Absorbed binder lies within the bulk aggregate volume.
Review air voids, VFA
Air voids is 5.6%. Screening limit is 3.9% to 4.1%.
Calculation ledger
Aggregate by mix mass
94.6%
Effective aggregate SG
2.7343
Absorbed binder by aggregate mass
1.198%
Dust-to-binder ratio
1.031
Minimum design VMA
14%
Lower design VFA limit
65%
Upper design VFA limit
78%
Inputs
Changes update results
Work through this example
Use Rice SG and binder fractions to calculate effective aggregate SG.
Compute air and mineral void volumes from the compacted specimen.
Correct binder for aggregate absorption and compare the volumetric screen.
Increase compacted SG to see air voids fall and the aggregate skeleton occupy more of the mix.
The screen uses the FHWA Superpave workbook limits and a ±0.1 percentage-point display band about 4.0% design air voids. Verify current agency mix specifications, gyrations, moisture susceptibility and any gradation exceptions.
Superpave HMA Mix Volumetrics · US customary units
Review air voids, VFA. Air voids is 5.6%. Screening limit is 3.9% to 4.1%.
Inputs
Binder by mix mass Pᵦ
5.4%
Binder SG Gᵦ
1.03
Bulk aggregate SG Gₛᵦ
2.65
No. 200 passing P₀.₀₇₅
4.4%
Rice maximum SG Gₘₘ
2.51
Compacted bulk SG Gₘᵦ
2.36944
Nominal max. size
12.5 mm · ½ in
Design traffic
0.3M to < 3M ESAL
Results
Air voids
5.6%
Voids in mineral aggregate
15.42%
Voids filled with asphalt
63.67%
Effective binder by mix mass
4.27%
Aggregate by mix mass
94.6%
Effective aggregate SG
2.7343
Absorbed binder by aggregate mass
1.198%
Dust-to-binder ratio
1.031
Minimum design VMA
14%
Lower design VFA limit
65%
Upper design VFA limit
78%
The screen uses the FHWA Superpave workbook limits and a ±0.1 percentage-point display band about 4.0% design air voids. Verify current agency mix specifications, gyrations, moisture susceptibility and any gradation exceptions.