VMA contains air plus effective binder. Absorbed binder lies within the bulk aggregate volume.
Volumetric screen met
Dust ratio is 0.923. Screening limit is 0.6 to 1.2.
Calculation ledger
Aggregate by mix mass
94.1%
Effective aggregate SG
2.7265
Absorbed binder by aggregate mass
1.09%
Dust-to-binder ratio
0.923
Minimum design VMA
15%
Lower design VFA limit
73%
Upper design VFA limit
76%
Inputs
Changes update results
Work through this example
Use Rice SG and binder fractions to calculate effective aggregate SG.
Compute air and mineral void volumes from the compacted specimen.
Correct binder for aggregate absorption and compare the volumetric screen.
The 9.5 mm high-traffic VFA screen is 73–76%. Change the traffic class to see the band change.
The screen uses the FHWA Superpave workbook limits and a ±0.1 percentage-point display band about 4.0% design air voids. Verify current agency mix specifications, gyrations, moisture susceptibility and any gradation exceptions.
Superpave HMA Mix Volumetrics · US customary units
Volumetric screen met. Dust ratio is 0.923. Screening limit is 0.6 to 1.2.
Inputs
Binder by mix mass Pᵦ
5.9%
Binder SG Gᵦ
1.03
Bulk aggregate SG Gₛᵦ
2.65
No. 200 passing P₀.₀₇₅
4.5%
Rice maximum SG Gₘₘ
2.485
Compacted bulk SG Gₘᵦ
2.3856
Nominal max. size
9.5 mm · ⅜ in
Design traffic
≥ 3M ESAL
Results
Air voids
4%
Voids in mineral aggregate
15.29%
Voids filled with asphalt
73.84%
Effective binder by mix mass
4.87%
Aggregate by mix mass
94.1%
Effective aggregate SG
2.7265
Absorbed binder by aggregate mass
1.09%
Dust-to-binder ratio
0.923
Minimum design VMA
15%
Lower design VFA limit
73%
Upper design VFA limit
76%
The screen uses the FHWA Superpave workbook limits and a ±0.1 percentage-point display band about 4.0% design air voids. Verify current agency mix specifications, gyrations, moisture susceptibility and any gradation exceptions.