25 mm low-volume base mix

Check a large nominal size in the lowest traffic band.

Design readout

Air voids
4
%
VMA
13
%
VFA
69.23
%
Eff. binder
3.83
%

Compacted mix phase blocks

Compacted mix phase blocksVOLUME FRACTIONSNMAS 1 inAIR4%EFF. BINDER9%BULK AGGREGATE87%VMA13%VFA69.23%DUST RATIO0.861
VMA contains air plus effective binder. Absorbed binder lies within the bulk aggregate volume.

Volumetric screen met

Dust ratio is 0.861. Screening limit is 0.6 to 1.2.

Calculation ledger
Aggregate by mix mass
95.3%
Effective aggregate SG
2.7136
Absorbed binder by aggregate mass
0.911%
Dust-to-binder ratio
0.861
Minimum design VMA
12%
Lower design VFA limit
67%
Upper design VFA limit
80%

Inputs

Changes update results

Binder and aggregate
%
%
Measured mix and design class

Work through this example

  1. Use Rice SG and binder fractions to calculate effective aggregate SG.
  2. Compute air and mineral void volumes from the compacted specimen.
  3. Correct binder for aggregate absorption and compare the volumetric screen.

The low-volume 25 mm case uses a 67% lower VFA limit. Compare against a 19 mm selection.

The screen uses the FHWA Superpave workbook limits and a ±0.1 percentage-point display band about 4.0% design air voids. Verify current agency mix specifications, gyrations, moisture susceptibility and any gradation exceptions.