Low-density specimen at 5.6% air

Evaluate a lower compacted bulk SG at the same Rice gravity and binder fraction.

Design readout

Air voids
5.6
%
VMA
15.42
%
VFA
63.67
%
Eff. binder
4.27
%

Compacted mix phase blocks

Compacted mix phase blocksVOLUME FRACTIONSNMAS ½ inAIR5.6%EFF. BINDER9.8%BULK AGGREGATE84.6%VMA15.42%VFA63.67%DUST RATIO1.031
VMA contains air plus effective binder. Absorbed binder lies within the bulk aggregate volume.

Review air voids, VFA

Air voids is 5.6%. Screening limit is 3.9% to 4.1%.

Calculation ledger
Aggregate by mix mass
94.6%
Effective aggregate SG
2.7343
Absorbed binder by aggregate mass
1.198%
Dust-to-binder ratio
1.031
Minimum design VMA
14%
Lower design VFA limit
65%
Upper design VFA limit
78%

Inputs

Changes update results

Binder and aggregate
%
%
Measured mix and design class

Work through this example

  1. Use Rice SG and binder fractions to calculate effective aggregate SG.
  2. Compute air and mineral void volumes from the compacted specimen.
  3. Correct binder for aggregate absorption and compare the volumetric screen.

Increase compacted SG to see air voids fall and the aggregate skeleton occupy more of the mix.

The screen uses the FHWA Superpave workbook limits and a ±0.1 percentage-point display band about 4.0% design air voids. Verify current agency mix specifications, gyrations, moisture susceptibility and any gradation exceptions.

Read the equations and sources