63 Hz Bass Trap Depth by the Quarter-Wavelength Rule

A room sweep shows a slow decay near 63 Hz. Use the measured frequency directly so the target depth stays tied to the sweep when you edit room dimensions.

Inputs

Room dimensions
ft
ft
ft
°F
Hz
Bass trap depth
Hz

Results

Quarter-wave depth
53.7in
Lowest axial mode
37.56Hz
Modes in plotted range
53
Short : middle : long
1 : 1.5 : 1.875
Bolt area (approx.)
Inside
Bonello density screen
Meets screen
Length mode
37.56Hz
Width mode
46.95Hz
Height mode
70.42Hz
Mode frequency distribution
Mode frequency distribution04080120160200AxialTangentialOblique37.6 HzFrequency (Hz)

Each stem marks a calculated resonance. Stem height increases where modes fall close together on the plot.

Bolt room proportion chart
Bolt room proportion chartLongest ÷ shortest11.21.41.61.8211.41.82.22.6Middle ÷ shortestPreferred regionYour room

The outline approximates Bolt’s historical preferred ratio region. The room point uses normalized, ordered dimensions.

Mode frequencies

Indices (p, q, r)TypeFrequency (Hz)
1, 0, 0Axial37.557
0, 1, 0Axial46.946
1, 1, 0Tangential60.12
0, 0, 1Axial70.419
2, 0, 0Axial75.114
1, 0, 1Tangential79.808
0, 1, 1Tangential84.633
2, 1, 0Tangential88.578
1, 1, 1Oblique92.592
0, 2, 0Axial93.892
1, 2, 0Tangential101.125
2, 0, 1Tangential102.961
3, 0, 0Axial112.671
2, 1, 1Oblique113.159
0, 2, 1Tangential117.365
2, 2, 0Tangential120.241
3, 1, 0Tangential122.06
1, 2, 1Oblique123.228
3, 0, 1Tangential132.867
2, 2, 1Oblique139.344
0, 3, 0Axial140.838
0, 0, 2Axial140.838
3, 1, 1Oblique140.916
1, 3, 0Tangential145.76
1, 0, 2Tangential145.76
3, 2, 0Tangential146.664
0, 1, 2Tangential148.457
4, 0, 0Axial150.227
1, 1, 2Oblique153.133
4, 1, 0Tangential157.392
0, 3, 1Tangential157.462
2, 3, 0Tangential159.617
2, 0, 2Tangential159.617
1, 3, 1Oblique161.879
3, 2, 1Oblique162.694
4, 0, 1Tangential165.913
2, 1, 2Oblique166.377
0, 2, 2Tangential169.267
4, 1, 1Oblique172.427
1, 2, 2Oblique173.383
2, 3, 1Oblique174.46
4, 2, 0Tangential177.155
3, 3, 0Tangential180.361
3, 0, 2Tangential180.361
2, 2, 2Oblique185.184
3, 1, 2Oblique186.371
0, 4, 0Axial187.784
5, 0, 0Axial187.784
4, 2, 1Oblique190.638
1, 4, 0Tangential191.503
5, 1, 0Tangential193.564
3, 3, 1Oblique193.621
0, 3, 2Tangential199.175

Bonello density by band

Band center (Hz)ModesCoincidencesCheck
1000Meets screen
12.500Meets screen
1600Meets screen
2000Meets screen
2500Meets screen
31.500Meets screen
4010Meets screen
5010Meets screen
6320Meets screen
8040Meets screen
10040Meets screen
125111Meets screen
160192Meets screen
200324Meets screen

Worked calculation

  1. Set sound speed

    c = 331.3 + 0.606 × 20 = 343.42 m/s

  2. Estimate porous trap depth

    d = c ÷ (4 × 63) = 1.363 m

What the example shows

The quarter-wave depth is about 1.36 m at 20 °C. In a real porous installation, an air gap and material flow resistance affect useful absorption, so compare measurements before and after fitting.

Model assumptions

  • Rigid rectangular boundaries are assumed. Frequencies locate possible resonances, while the source, listener and boundary losses determine their measured strength.
  • The Bonello screen uses complete third-octave bands from 10 to 200 Hz, independent of the plot limit. It permits equal counts and flags coincident modes in bands with fewer than five modes.
  • Bolt uses the shortest, middle and longest sides and a digitized outline. The quarter-wavelength result is a depth scale for porous treatment in air, and absorber construction affects performance.