63 Hz Bass Trap Depth by the Quarter-Wavelength Rule
A room sweep shows a slow decay near 63 Hz. Use the measured frequency directly so the target depth stays tied to the sweep when you edit room dimensions.
- Length
- 15 ft
- Width
- 12 ft
- Height
- 8 ft
- Air temperature
- 68 °F
- Plot and table limit
- 200 Hz
- Frequency source
- Enter a frequency
- Target frequency
- 63 Hz
Results
- Quarter-wave depth
- 53.7in
- Lowest axial mode
- 37.56Hz
- Modes in plotted range
- 53
- Short : middle : long
- 1 : 1.5 : 1.875
- Bolt area (approx.)
- Inside
- Bonello density screen
- Meets screen
- Length mode
- 37.56Hz
- Width mode
- 46.95Hz
- Height mode
- 70.42Hz
Each stem marks a calculated resonance. Stem height increases where modes fall close together on the plot.
The outline approximates Bolt’s historical preferred ratio region. The room point uses normalized, ordered dimensions.
Mode frequencies
| Indices (p, q, r) | Type | Frequency (Hz) |
|---|---|---|
| 1, 0, 0 | Axial | 37.557 |
| 0, 1, 0 | Axial | 46.946 |
| 1, 1, 0 | Tangential | 60.12 |
| 0, 0, 1 | Axial | 70.419 |
| 2, 0, 0 | Axial | 75.114 |
| 1, 0, 1 | Tangential | 79.808 |
| 0, 1, 1 | Tangential | 84.633 |
| 2, 1, 0 | Tangential | 88.578 |
| 1, 1, 1 | Oblique | 92.592 |
| 0, 2, 0 | Axial | 93.892 |
| 1, 2, 0 | Tangential | 101.125 |
| 2, 0, 1 | Tangential | 102.961 |
| 3, 0, 0 | Axial | 112.671 |
| 2, 1, 1 | Oblique | 113.159 |
| 0, 2, 1 | Tangential | 117.365 |
| 2, 2, 0 | Tangential | 120.241 |
| 3, 1, 0 | Tangential | 122.06 |
| 1, 2, 1 | Oblique | 123.228 |
| 3, 0, 1 | Tangential | 132.867 |
| 2, 2, 1 | Oblique | 139.344 |
| 0, 3, 0 | Axial | 140.838 |
| 0, 0, 2 | Axial | 140.838 |
| 3, 1, 1 | Oblique | 140.916 |
| 1, 3, 0 | Tangential | 145.76 |
| 1, 0, 2 | Tangential | 145.76 |
| 3, 2, 0 | Tangential | 146.664 |
| 0, 1, 2 | Tangential | 148.457 |
| 4, 0, 0 | Axial | 150.227 |
| 1, 1, 2 | Oblique | 153.133 |
| 4, 1, 0 | Tangential | 157.392 |
| 0, 3, 1 | Tangential | 157.462 |
| 2, 3, 0 | Tangential | 159.617 |
| 2, 0, 2 | Tangential | 159.617 |
| 1, 3, 1 | Oblique | 161.879 |
| 3, 2, 1 | Oblique | 162.694 |
| 4, 0, 1 | Tangential | 165.913 |
| 2, 1, 2 | Oblique | 166.377 |
| 0, 2, 2 | Tangential | 169.267 |
| 4, 1, 1 | Oblique | 172.427 |
| 1, 2, 2 | Oblique | 173.383 |
| 2, 3, 1 | Oblique | 174.46 |
| 4, 2, 0 | Tangential | 177.155 |
| 3, 3, 0 | Tangential | 180.361 |
| 3, 0, 2 | Tangential | 180.361 |
| 2, 2, 2 | Oblique | 185.184 |
| 3, 1, 2 | Oblique | 186.371 |
| 0, 4, 0 | Axial | 187.784 |
| 5, 0, 0 | Axial | 187.784 |
| 4, 2, 1 | Oblique | 190.638 |
| 1, 4, 0 | Tangential | 191.503 |
| 5, 1, 0 | Tangential | 193.564 |
| 3, 3, 1 | Oblique | 193.621 |
| 0, 3, 2 | Tangential | 199.175 |
Bonello density by band
| Band center (Hz) | Modes | Coincidences | Check |
|---|---|---|---|
| 10 | 0 | 0 | Meets screen |
| 12.5 | 0 | 0 | Meets screen |
| 16 | 0 | 0 | Meets screen |
| 20 | 0 | 0 | Meets screen |
| 25 | 0 | 0 | Meets screen |
| 31.5 | 0 | 0 | Meets screen |
| 40 | 1 | 0 | Meets screen |
| 50 | 1 | 0 | Meets screen |
| 63 | 2 | 0 | Meets screen |
| 80 | 4 | 0 | Meets screen |
| 100 | 4 | 0 | Meets screen |
| 125 | 11 | 1 | Meets screen |
| 160 | 19 | 2 | Meets screen |
| 200 | 32 | 4 | Meets screen |
Worked calculation
Set sound speed
c = 331.3 + 0.606 × 20 = 343.42 m/s
Estimate porous trap depth
d = c ÷ (4 × 63) = 1.363 m
What the example shows
The quarter-wave depth is about 1.36 m at 20 °C. In a real porous installation, an air gap and material flow resistance affect useful absorption, so compare measurements before and after fitting.
Model assumptions
- Rigid rectangular boundaries are assumed. Frequencies locate possible resonances, while the source, listener and boundary losses determine their measured strength.
- The Bonello screen uses complete third-octave bands from 10 to 200 Hz, independent of the plot limit. It permits equal counts and flags coincident modes in bands with fewer than five modes.
- Bolt uses the shortest, middle and longest sides and a digitized outline. The quarter-wavelength result is a depth scale for porous treatment in air, and absorber construction affects performance.
Common questions
Do I set trap frequency from the 63 Hz measured peak or a nearby predicted mode?
Use the measured decay frequency as the treatment target when you have a repeatable sweep. Its relationship to predicted modes can help explain where to look next.
How does a 63 Hz quarter-wave depth change in cooler air?
Lower temperature reduces the speed of sound and therefore the wavelength and depth. The change is usually modest over indoor temperatures.