125 Hz Panel Coverage in a Small Studio

At 125 Hz, the proposed 8 ft² panels have a tested coefficient of only 0.25. Use the low-band coefficient and check how much wall area the decay target would require.

Inputs

Room geometry
ft
ft
ft
Existing absorption
ft² sabins
Panel coverage
s
ft²

Results

Added panel coverage needed
439.55ft²
Area of mounting surface
320ft²
RT60 after fitting 40 panels
0.452s
Current Sabine RT60
2.074s
Whole panels needed
55
Sabine RT60
2.074s
Eyring RT60
2.036s
Current total absorption
18.74ft² sabins
Surface area check
Over capacity
Reverberation time and target band
Reverberation time and target band125 Hz · target 0.35 sSabine nowEyring nowSabine after00.581.161.742.32RT60 (seconds)

The shaded range is ±10% around the entered RT60 target. The after-fit trace uses 40 complete panels.

Surface absorption at 125 Hz

SurfaceArea (ft²)Absorption coefficientEquivalent absorption (ft² sabins)
Floor990.032.97
Walls3200.0412.8
Ceiling990.032.97
Objects——0

Worked calculation

  1. Weight each surface by its absorption coefficient

    A = 9.197 × 0.03 + 29.729 × 0.04 + 9.197 × 0.03 = 1.741 m² sabins before 0 m² sabins of objects

  2. Calculate the decay time at 125 Hz

    T = 0.161 × 22.427 ÷ (1.741 + 0) = 2.0739 s

  3. Solve the required area and round up to whole units

    Required surface absorption = 10.316 m² sabins. ΔA = 8.575. Dividing by Δα = 0.21 gives 40.835 m². Round up at 0.7432 m² per panel → 55 units.

What the example shows

The model asks for more panel area than the walls offer. In a room this small, measure modal decay and consider deeper or tuned treatment before relying on a diffuse-field estimate.

Model assumptions

  • The required whole-panel count exceeds the area of this surface. The after-fit estimate uses the maximum count allowed by area.
  • Each coefficient describes the selected frequency band. Use measured or published coefficients for that band and mounting method.
  • Coverage is based on the improvement over the surface the panel covers. Panel count rounds up. The after-fit estimate uses only complete panels that fit by area.
  • Both models assume a diffuse field. Small studios can have uneven decay at bass frequencies and panel geometry, gaps and layout reduce practical capacity.