125 Hz Panel Coverage in a Small Studio
At 125 Hz, the proposed 8 ft² panels have a tested coefficient of only 0.25. Use the low-band coefficient and check how much wall area the decay target would require.
- Length
- 11 ft
- Width
- 9 ft
- Height
- 8 ft
- Absorption frequency band
- 125 Hz
- Floor absorption coefficient
- 0.03
- Wall absorption coefficient
- 0.04
- Ceiling absorption coefficient
- 0.03
- Furniture and people absorption
- 0 ft² sabins
- Treatment sizing model
- Sabine
- Target RT60
- 0.35 s
- Panel absorption coefficient
- 0.25
- Mount panels on
- Walls
- Face area per panel
- 8 ft²
Results
- Added panel coverage needed
- 439.55ft²
- Area of mounting surface
- 320ft²
- RT60 after fitting 40 panels
- 0.452s
- Current Sabine RT60
- 2.074s
- Whole panels needed
- 55
- Sabine RT60
- 2.074s
- Eyring RT60
- 2.036s
- Current total absorption
- 18.74ft² sabins
- Surface area check
- Over capacity
The shaded range is ±10% around the entered RT60 target. The after-fit trace uses 40 complete panels.
Surface absorption at 125 Hz
| Surface | Area (ft²) | Absorption coefficient | Equivalent absorption (ft² sabins) |
|---|---|---|---|
| Floor | 99 | 0.03 | 2.97 |
| Walls | 320 | 0.04 | 12.8 |
| Ceiling | 99 | 0.03 | 2.97 |
| Objects | — | — | 0 |
Worked calculation
Weight each surface by its absorption coefficient
A = 9.197 × 0.03 + 29.729 × 0.04 + 9.197 × 0.03 = 1.741 m² sabins before 0 m² sabins of objects
Calculate the decay time at 125 Hz
T = 0.161 × 22.427 ÷ (1.741 + 0) = 2.0739 s
Solve the required area and round up to whole units
Required surface absorption = 10.316 m² sabins. ΔA = 8.575. Dividing by Δα = 0.21 gives 40.835 m². Round up at 0.7432 m² per panel → 55 units.
What the example shows
The model asks for more panel area than the walls offer. In a room this small, measure modal decay and consider deeper or tuned treatment before relying on a diffuse-field estimate.
Model assumptions
- The required whole-panel count exceeds the area of this surface. The after-fit estimate uses the maximum count allowed by area.
- Each coefficient describes the selected frequency band. Use measured or published coefficients for that band and mounting method.
- Coverage is based on the improvement over the surface the panel covers. Panel count rounds up. The after-fit estimate uses only complete panels that fit by area.
- Both models assume a diffuse field. Small studios can have uneven decay at bass frequencies and panel geometry, gaps and layout reduce practical capacity.
Common questions
Can I substitute the panel’s 1 kHz coefficient in the 125 Hz calculation?
Use the same frequency band for every material. A high midband coefficient can substantially overstate low-frequency absorption.
What does Over capacity mean for the 11 × 9 ft studio?
The whole panels needed by the model occupy more face area than the selected walls. The after-fit number uses the maximum count by gross wall area.