Acoustic Panels for a 200 ft² Vocal Room at 0.30 s RT60
A vocal room has 200 ft² of floor area and an 8 ft ceiling. Start with illustrative hard-surface coefficients and 20 ft² sabins for furniture, then aim for 0.30 s at 500 Hz.
- Length
- 20 ft
- Width
- 10 ft
- Height
- 8 ft
- Absorption frequency band
- 500 Hz
- Floor absorption coefficient
- 0.05
- Wall absorption coefficient
- 0.05
- Ceiling absorption coefficient
- 0.05
- Furniture and people absorption
- 20 ft² sabins
- Treatment sizing model
- Sabine
- Target RT60
- 0.3 s
- Panel absorption coefficient
- 0.85
- Mount panels on
- Walls
- Face area per panel
- 8 ft²
Results
- Current Sabine RT60
- 1.227s
- Added panel coverage needed
- 247.15ft²
- Whole panels needed
- 31
- RT60 after fitting 31 panels
- 0.299s
- Sabine RT60
- 1.227s
- Eyring RT60
- 1.205s
- Current total absorption
- 64ft² sabins
- Area of mounting surface
- 480ft²
- Surface area check
- Fits by area
The shaded range is ±10% around the entered RT60 target. The after-fit trace uses 31 complete panels.
Surface absorption at 500 Hz
| Surface | Area (ft²) | Absorption coefficient | Equivalent absorption (ft² sabins) |
|---|---|---|---|
| Floor | 200 | 0.05 | 10 |
| Walls | 480 | 0.05 | 24 |
| Ceiling | 200 | 0.05 | 10 |
| Objects | — | — | 20 |
Worked calculation
Calculate volume and room surface area
V = 6.096 × 3.048 × 2.4384 = 45.307 m³. S = 2(LW + LH + WH) = 81.755 m²
Weight each surface by its absorption coefficient
A = 18.581 × 0.05 + 44.593 × 0.05 + 18.581 × 0.05 = 4.088 m² sabins before 1.858 m² sabins of objects
Calculate the decay time at 500 Hz
T = 0.161 × 45.307 ÷ (4.088 + 1.858) = 1.2268 s
Solve the required area and round up to whole units
Required surface absorption = 22.457 m² sabins. ΔA = 18.369. Dividing by Δα = 0.8 gives 22.961 m². Round up at 0.7432 m² per panel → 31 units.
What the example shows
The 4 × 2 ft panels add only the difference between their 0.85 coefficient and the 0.05 wall they cover. Use the rounded-up count and confirm with an in-room decay measurement.
Model assumptions
- Each coefficient describes the selected frequency band. Use measured or published coefficients for that band and mounting method.
- Coverage is based on the improvement over the surface the panel covers. Panel count rounds up. The after-fit estimate uses only complete panels that fit by area.
- Both models assume a diffuse field. Small studios can have uneven decay at bass frequencies and panel geometry, gaps and layout reduce practical capacity.
Common questions
Why does the 200 ft² vocal room need more panel area than its floor area?
The treatment target applies to the room volume and losses across all surfaces. Its wall area is 480 ft², so the modeled panel coverage can exceed the floor footprint.
Does the 0.30 s estimate apply equally at 125 Hz?
The coefficients in this preset describe 500 Hz. Use the actual 125 Hz coefficients and pay attention to modal behavior in that low band.