Acoustic Panels for a 200 ft² Vocal Room at 0.30 s RT60

A vocal room has 200 ft² of floor area and an 8 ft ceiling. Start with illustrative hard-surface coefficients and 20 ft² sabins for furniture, then aim for 0.30 s at 500 Hz.

Inputs

Room geometry
ft
ft
ft
Existing absorption
ft² sabins
Panel coverage
s
ft²

Results

Current Sabine RT60
1.227s
Added panel coverage needed
247.15ft²
Whole panels needed
31
RT60 after fitting 31 panels
0.299s
Sabine RT60
1.227s
Eyring RT60
1.205s
Current total absorption
64ft² sabins
Area of mounting surface
480ft²
Surface area check
Fits by area
Reverberation time and target band
Reverberation time and target band500 Hz · target 0.3 sSabine nowEyring nowSabine after00.340.691.031.37RT60 (seconds)

The shaded range is ±10% around the entered RT60 target. The after-fit trace uses 31 complete panels.

Surface absorption at 500 Hz

SurfaceArea (ft²)Absorption coefficientEquivalent absorption (ft² sabins)
Floor2000.0510
Walls4800.0524
Ceiling2000.0510
Objects——20

Worked calculation

  1. Calculate volume and room surface area

    V = 6.096 × 3.048 × 2.4384 = 45.307 m³. S = 2(LW + LH + WH) = 81.755 m²

  2. Weight each surface by its absorption coefficient

    A = 18.581 × 0.05 + 44.593 × 0.05 + 18.581 × 0.05 = 4.088 m² sabins before 1.858 m² sabins of objects

  3. Calculate the decay time at 500 Hz

    T = 0.161 × 45.307 ÷ (4.088 + 1.858) = 1.2268 s

  4. Solve the required area and round up to whole units

    Required surface absorption = 22.457 m² sabins. ΔA = 18.369. Dividing by Δα = 0.8 gives 22.961 m². Round up at 0.7432 m² per panel → 31 units.

What the example shows

The 4 × 2 ft panels add only the difference between their 0.85 coefficient and the 0.05 wall they cover. Use the rounded-up count and confirm with an in-room decay measurement.

Model assumptions

  • Each coefficient describes the selected frequency band. Use measured or published coefficients for that band and mounting method.
  • Coverage is based on the improvement over the surface the panel covers. Panel count rounds up. The after-fit estimate uses only complete panels that fit by area.
  • Both models assume a diffuse field. Small studios can have uneven decay at bass frequencies and panel geometry, gaps and layout reduce practical capacity.