Sabine RT60 for a Bare 5 × 4 × 3 m Room

A mostly empty room has a 5 × 4 m footprint and a 3 m ceiling. Use separate coefficients for the floor, walls and ceiling to add equivalent absorption area.

Inputs

Room geometry
m
m
m
Existing absorption
m² sabins
Panel coverage
s
m²

Results

Current Sabine RT60
2.569s
Added panel coverage needed
19.21m²
Whole panels needed
27
RT60 after fitting 27 panels
0.495s
Sabine RT60
2.569s
Eyring RT60
2.517s
Current total absorption
3.76m² sabins
Area of mounting surface
54m²
Surface area check
Fits by area
Reverberation time and target band
Reverberation time and target band500 Hz · target 0.5 sSabine nowEyring nowSabine after00.721.442.162.88RT60 (seconds)

The shaded range is ±10% around the entered RT60 target. The after-fit trace uses 27 complete panels.

Surface absorption at 500 Hz

SurfaceArea (m²)Absorption coefficientEquivalent absorption (m² sabins)
Floor200.030.6
Walls540.042.16
Ceiling200.051
Objects——0

Worked calculation

  1. Calculate volume and room surface area

    V = 5 × 4 × 3 = 60 m³. S = 2(LW + LH + WH) = 94 m²

  2. Weight each surface by its absorption coefficient

    A = 20 × 0.03 + 54 × 0.04 + 20 × 0.05 = 3.76 m² sabins before 0 m² sabins of objects

  3. Calculate the decay time at 500 Hz

    T = 0.161 × 60 ÷ (3.76 + 0) = 2.5691 s

What the example shows

A 94 m² envelope yields only 3.76 metric sabins with these finishes. That small absorption denominator explains the long modeled decay.

Model assumptions

  • Each coefficient describes the selected frequency band. Use measured or published coefficients for that band and mounting method.
  • Coverage is based on the improvement over the surface the panel covers. Panel count rounds up. The after-fit estimate uses only complete panels that fit by area.
  • Both models assume a diffuse field. Small studios can have uneven decay at bass frequencies and panel geometry, gaps and layout reduce practical capacity.