How Furniture Sabins Change a Live Room’s RT60
A recording room uses movable furniture and absorptive seating. Enter 12 m² sabins of equivalent absorption at 500 Hz and compare the result with an empty room.
- Length
- 8 m
- Width
- 5 m
- Height
- 3 m
- Absorption frequency band
- 500 Hz
- Floor absorption coefficient
- 0.07
- Wall absorption coefficient
- 0.1
- Ceiling absorption coefficient
- 0.08
- Furniture and people absorption
- 12 m² sabins
- Treatment sizing model
- Sabine
- Target RT60
- 0.7 s
- Panel absorption coefficient
- 0.85
- Mount panels on
- Walls
- Face area per panel
- 0.72 m²
Results
- Current total absorption
- 25.8m² sabins
- Current Sabine RT60
- 0.749s
- Added panel coverage needed
- 2.4m²
- Whole panels needed
- 4
- RT60 after fitting 4 panels
- 0.691s
- Sabine RT60
- 0.749s
- Eyring RT60
- 0.731s
- Area of mounting surface
- 78m²
- Surface area check
- Fits by area
The shaded range is ±10% around the entered RT60 target. The after-fit trace uses 4 complete panels.
Surface absorption at 500 Hz
| Surface | Area (m²) | Absorption coefficient | Equivalent absorption (m² sabins) |
|---|---|---|---|
| Floor | 40 | 0.07 | 2.8 |
| Walls | 78 | 0.1 | 7.8 |
| Ceiling | 40 | 0.08 | 3.2 |
| Objects | — | — | 12 |
Worked calculation
Calculate volume and room surface area
V = 8 × 5 × 3 = 120 m³. S = 2(LW + LH + WH) = 158 m²
Weight each surface by its absorption coefficient
A = 40 × 0.07 + 78 × 0.1 + 40 × 0.08 = 13.8 m² sabins before 12 m² sabins of objects
Calculate the decay time at 500 Hz
T = 0.161 × 120 ÷ (13.8 + 12) = 0.7488 s
What the example shows
Standalone object absorption adds to the Sabine denominator. Change the object input to zero to compare the room after moving the furnishings out.
Model assumptions
- Each coefficient describes the selected frequency band. Use measured or published coefficients for that band and mounting method.
- Coverage is based on the improvement over the surface the panel covers. Panel count rounds up. The after-fit estimate uses only complete panels that fit by area.
- Both models assume a diffuse field. Small studios can have uneven decay at bass frequencies and panel geometry, gaps and layout reduce practical capacity.
Common questions
Do 12 square meters of furniture equal 12 metric sabins?
Only if the total equivalent absorption is 12 m² at the stated frequency. Physical footprint and equivalent absorption are different quantities.
Why enter movable seating as object absorption in this live room?
It contributes loss without occupying the modeled floor, wall or ceiling boundary area as a replacement finish.