How Furniture Sabins Change a Live Room’s RT60

A recording room uses movable furniture and absorptive seating. Enter 12 m² sabins of equivalent absorption at 500 Hz and compare the result with an empty room.

Inputs

Room geometry
m
m
m
Existing absorption
m² sabins
Panel coverage
s
m²

Results

Current total absorption
25.8m² sabins
Current Sabine RT60
0.749s
Added panel coverage needed
2.4m²
Whole panels needed
4
RT60 after fitting 4 panels
0.691s
Sabine RT60
0.749s
Eyring RT60
0.731s
Area of mounting surface
78m²
Surface area check
Fits by area
Reverberation time and target band
Reverberation time and target band500 Hz · target 0.7 sSabine nowEyring nowSabine after00.220.440.660.88RT60 (seconds)

The shaded range is ±10% around the entered RT60 target. The after-fit trace uses 4 complete panels.

Surface absorption at 500 Hz

SurfaceArea (m²)Absorption coefficientEquivalent absorption (m² sabins)
Floor400.072.8
Walls780.17.8
Ceiling400.083.2
Objects——12

Worked calculation

  1. Calculate volume and room surface area

    V = 8 × 5 × 3 = 120 m³. S = 2(LW + LH + WH) = 158 m²

  2. Weight each surface by its absorption coefficient

    A = 40 × 0.07 + 78 × 0.1 + 40 × 0.08 = 13.8 m² sabins before 12 m² sabins of objects

  3. Calculate the decay time at 500 Hz

    T = 0.161 × 120 ÷ (13.8 + 12) = 0.7488 s

What the example shows

Standalone object absorption adds to the Sabine denominator. Change the object input to zero to compare the room after moving the furnishings out.

Model assumptions

  • Each coefficient describes the selected frequency band. Use measured or published coefficients for that band and mounting method.
  • Coverage is based on the improvement over the surface the panel covers. Panel count rounds up. The after-fit estimate uses only complete panels that fit by area.