RT60, Sabine & Acoustic Treatment Calculator
Estimate RT60 with Sabine and Eyring, total absorption in sabins, and the acoustic panel area and count needed for a room decay target.
- Length
- 20 ft
- Width
- 10 ft
- Height
- 8 ft
- Absorption frequency band
- 500 Hz
- Floor absorption coefficient
- 0.05
- Wall absorption coefficient
- 0.05
- Ceiling absorption coefficient
- 0.05
- Furniture and people absorption
- 20 ft² sabins
- Treatment sizing model
- Sabine
- Target RT60
- 0.3 s
- Panel absorption coefficient
- 0.85
- Mount panels on
- Walls
- Face area per panel
- 8 ft²
Results
- Current Sabine RT60
- 1.227s
- Added panel coverage needed
- 247.15ft²
- Whole panels needed
- 31
- RT60 after fitting 31 panels
- 0.299s
- Sabine RT60
- 1.227s
- Eyring RT60
- 1.205s
- Current total absorption
- 64ft² sabins
- Area of mounting surface
- 480ft²
- Surface area check
- Fits by area
The shaded range is ±10% around the entered RT60 target. The after-fit trace uses 31 complete panels.
Surface absorption at 500 Hz
| Surface | Area (ft²) | Absorption coefficient | Equivalent absorption (ft² sabins) |
|---|---|---|---|
| Floor | 200 | 0.05 | 10 |
| Walls | 480 | 0.05 | 24 |
| Ceiling | 200 | 0.05 | 10 |
| Objects | — | — | 20 |
Calculation steps
Calculate volume and room surface area
V = 6.096 × 3.048 × 2.4384 = 45.307 m³. S = 2(LW + LH + WH) = 81.755 m²
Weight each surface by its absorption coefficient
A = 18.581 × 0.05 + 44.593 × 0.05 + 18.581 × 0.05 = 4.088 m² sabins before 1.858 m² sabins of objects
Calculate the decay time at 500 Hz
T = 0.161 × 45.307 ÷ (4.088 + 1.858) = 1.2268 s
Solve the required area and round up to whole units
Required surface absorption = 22.457 m² sabins. ΔA = 18.369. Dividing by Δα = 0.8 gives 22.961 m². Round up at 0.7432 m² per panel → 31 units.
Model assumptions
- Each coefficient describes the selected frequency band. Use measured or published coefficients for that band and mounting method.
- Coverage is based on the improvement over the surface the panel covers. Panel count rounds up. The after-fit estimate uses only complete panels that fit by area.
- Both models assume a diffuse field. Small studios can have uneven decay at bass frequencies and panel geometry, gaps and layout reduce practical capacity.
Common questions
What is a sabin in metric and US units?
One metric sabin is the equivalent absorption of one square meter with coefficient 1. A US sabin uses one square foot. The unit switch converts the result and any entered object absorption.
When do Sabine and Eyring give noticeably different results?
At low average absorption, the models are close. As surface absorption rises, the Eyring logarithm predicts faster decay than Sabine for the same coefficients.
Why does panel area depend on where I mount the panels?