Ceiling Cloud Coverage for a 0.45 s Podcast Room
A 14 × 11 ft podcast room reserves the walls for set pieces. Estimate the ceiling coverage needed to reach 0.45 s at 1 kHz with 8 ft² overhead panels.
- Length
- 14 ft
- Width
- 11 ft
- Height
- 9 ft
- Absorption frequency band
- 1000 Hz
- Floor absorption coefficient
- 0.18
- Wall absorption coefficient
- 0.13
- Ceiling absorption coefficient
- 0.05
- Furniture and people absorption
- 12 ft² sabins
- Treatment sizing model
- Sabine
- Target RT60
- 0.45 s
- Panel absorption coefficient
- 0.9
- Mount panels on
- Ceiling
- Face area per panel
- 8 ft²
Results
- Current Sabine RT60
- 0.642s
- Added panel coverage needed
- 53.2ft²
- Whole panels needed
- 7
- RT60 after fitting 7 panels
- 0.443s
- Sabine RT60
- 0.642s
- Eyring RT60
- 0.606s
- Current total absorption
- 105.92ft² sabins
- Area of mounting surface
- 154ft²
- Surface area check
- Fits by area
The shaded range is ±10% around the entered RT60 target. The after-fit trace uses 7 complete panels.
Surface absorption at 1000 Hz
| Surface | Area (ft²) | Absorption coefficient | Equivalent absorption (ft² sabins) |
|---|---|---|---|
| Floor | 154 | 0.18 | 27.72 |
| Walls | 450 | 0.13 | 58.5 |
| Ceiling | 154 | 0.05 | 7.7 |
| Objects | — | — | 12 |
Worked calculation
Calculate volume and room surface area
V = 4.2672 × 3.3528 × 2.7432 = 39.247 m³. S = 2(LW + LH + WH) = 70.421 m²
Calculate the decay time at 1000 Hz
T = 0.161 × 39.247 ÷ (8.725 + 1.115) = 0.6421 s
Solve the required area and round up to whole units
Required surface absorption = 12.927 m² sabins. ΔA = 4.201. Dividing by Δα = 0.85 gives 4.943 m². Round up at 0.7432 m² per panel → 7 units.
What the example shows
The available ceiling face is 154 ft² before lights and obstructions. Use the estimate to sketch a layout, then enter your actual usable geometry and panel data.
Model assumptions
- Each coefficient describes the selected frequency band. Use measured or published coefficients for that band and mounting method.
- Coverage is based on the improvement over the surface the panel covers. Panel count rounds up. The after-fit estimate uses only complete panels that fit by area.
- Both models assume a diffuse field. Small studios can have uneven decay at bass frequencies and panel geometry, gaps and layout reduce practical capacity.
Common questions
Do I count both sides of an exposed overhead cloud as ceiling face area?
The worksheet uses the projected face area and an effective coefficient for the mounting condition. Use the manufacturer’s tested equivalent absorption for a suspended cloud when planning a detailed build.
How many 8 ft² panels can the 154 ft² ceiling fit by area?
At most 19 whole faces by area. Shape, mounting clearances and ceiling fixtures can reduce the actual layout.