Eyring vs. Sabine in a Treated Room With α = 0.40
Use an illustrative homogeneous absorption of 0.40 on the surfaces of a treated 6 × 4 × 2.8 m room. Compare the current decay estimates before choosing a model for the extra treatment.
- Length
- 6 m
- Width
- 4 m
- Height
- 2.8 m
- Absorption frequency band
- 500 Hz
- Floor absorption coefficient
- 0.4
- Wall absorption coefficient
- 0.4
- Ceiling absorption coefficient
- 0.4
- Furniture and people absorption
- 0 m² sabins
- Treatment sizing model
- Eyring
- Target RT60
- 0.2 s
- Panel absorption coefficient
- 0.9
- Mount panels on
- Walls
- Face area per panel
- 0.72 m²
Results
- Sabine RT60
- 0.26s
- Eyring RT60
- 0.204s
- Added panel coverage needed
- 1.16m²
- Current Eyring RT60
- 0.204s
- Whole panels needed
- 2
- RT60 after fitting 2 panels
- 0.199s
- Current total absorption
- 41.6m² sabins
- Area of mounting surface
- 56m²
- Surface area check
- Fits by area
The shaded range is ±10% around the entered RT60 target. The after-fit trace uses 2 complete panels.
Surface absorption at 500 Hz
| Surface | Area (m²) | Absorption coefficient | Equivalent absorption (m² sabins) |
|---|---|---|---|
| Floor | 24 | 0.4 | 9.6 |
| Walls | 56 | 0.4 | 22.4 |
| Ceiling | 24 | 0.4 | 9.6 |
| Objects | — | — | 0 |
Worked calculation
Calculate volume and room surface area
V = 6 × 4 × 2.8 = 67.2 m³. S = 2(LW + LH + WH) = 104 m²
Calculate the decay time at 500 Hz
T = 0.161 × 67.2 ÷ [−104 × ln(1 − 0.4) + 0] = 0.2037 s
Solve the required area and round up to whole units
Required surface absorption = 42.179 m² sabins. ΔA = 0.579. Dividing by Δα = 0.5 gives 1.159 m². Round up at 0.72 m² per panel → 2 units.
What the example shows
Eyring uses −ln(1 − 0.4) ≈ 0.511 where Sabine uses 0.4. That makes the Eyring estimate shorter in this example.
Model assumptions
- Each coefficient describes the selected frequency band. Use measured or published coefficients for that band and mounting method.
- Coverage is based on the improvement over the surface the panel covers. Panel count rounds up. The after-fit estimate uses only complete panels that fit by area.
- Both models assume a diffuse field. Small studios can have uneven decay at bass frequencies and panel geometry, gaps and layout reduce practical capacity.
Common questions
Why does α = 0.40 become approximately 0.511 in the Eyring denominator?
The logarithm accounts for multiplying the energy retained at each reflection. Its effective loss term is −ln(1 − α).
Will the panel estimate change if I switch this treated room back to Sabine?
Yes. Sabine uses a different loss term, so the raw absorption needed for the same target decay will change.