D is flight OD, d is shaft OD, p is flight pitch, N is rpm, and f is 15%, 30% or 45% loading. In metres this gives m³/h. The default retained fraction k is interpolated through 100%, 95%, 75%, 60% and 35% at 0°, 10°, 20°, 30° and 45°. These are illustrative values. Pitch, housing, fallback and material tests can change the derate.
Empty and material horsepower
HPf = Fd Fb L N / 10⁶ | HPm = ṁ Fm L / 10⁶
The KWS control-fed convention uses L in feet, ṁ in lb/h and empirical diameter, hanger and material factors. Diameter factor is interpolated through the published screw diameters. The optional multiplier applies to material power. Obtain OEM correction for low material HP, startup and flood feeding.
Gravity, motor and shaft torque
Plift = ṁ g L sin α | Pshaft = Pf + multiplier · Pm + Plift
Pmotor = Pshaft/η | τ = Pshaft/(2πN/60)
Use kg/s for ṁ and watts for the SI torque equation. Torque is at the screw shaft, after the drive losses used to estimate motor size.
Compared with the same screw operating horizontally.
Inputs
Screw OD
9 in
Pipe shaft OD
2.5 in
Flight pitch
9 in
Trough loading
15%
Screw speed
58 RPM
Incline angle
0°
Conveyor length
18 ft
Bulk density
105 lb/ft³
Incline capacity retained
0%
Material factor Fm
3.2
Hanger bearing factor
1.7
Material power multiplier
1.3
Drive efficiency
88%
Calculated values
Volume throughput
159.614CFH
Mass throughput
8.38TPH
Screw shaft torque
1,423.467lb-in
Motor power
1.489HP
Open flight annulus
0.408ft²
Incline capacity retained
100%
Effective fill after derate
15%
Diameter factor
31
Empty screw power
0.055HP
Material power before multiplier
0.965HP
Vertical rise
0ft
Gravity lift power
0HP
Screw shaft power
1.31HP
Industrial machinery and mobile equipment can cause fatal injuries. Use these estimates for preliminary sizing. Follow the MSHA or OSHA requirements that apply at your site. Guard moving parts and nip points, and use site lockout/tagout and hazardous-energy isolation procedures before service. Have qualified personnel verify equipment selection and operating limits.