The default C₀ is 2.2 × aperture(in)^0.55 short tons/h/ft². Reference conditions are 25% oversize, 40% half-size, 100 lb/ft³, top deck, dry screening and 90% recovery. Fo = 1 + 0.5(oversize fraction − 0.25), Fh = 1 + (half-size fraction − 0.40), and Fd = 1/0.9/0.8 by deck position (top/second/third respectively). Wet spray uses Fw = 1 + 0.3/(1 + aperture(in)²). Fρ scales with bulk density. The curve and corrections are illustrative VSMA-style estimates. Use an OEM rating and validate motion, media open area, bed depth and blinding before selection.
fᵤ is the fraction smaller than the aperture. This first-pass recovery curve is anchored at 90% for A₉₀. Its estimated recovery depends on the installed live area. Use a sampled and weighed feed and product mass balance to establish plant efficiency.
This model assumes coarse particles remain above the aperture. The oversize product includes unrecovered fines. Feed, passing and retained rates use the same mass basis.
Installed deck is below the estimated target area.
Inputs
Feed rate
105 TPH
Undersize in feed
63%
Half-size in feed
32%
Screen aperture
0.19 in
Bulk density
91 lb/ft³
Deck position
Third deck
Screening mode
Dry
Installed live deck area
79 ft²
Target passing efficiency
92%
OEM base screen rating
0 TPH/ft²
Calculated values
Required live deck area
116.655ft²
Estimated passing efficiency
81.922%
Undersize product
54.191TPH
Oversize product
50.809TPH
True undersize in feed
66.15TPH
Undersize retained on deck
11.959TPH
Deck area at 90% recovery
106.349ft²
Aperture base capacity
0.876TPH/ft²
Corrected unit capacity
0.622TPH/ft²
Oversize correction
1.06
Half-size correction
0.92
Deck position correction
0.8
Wet screening correction
1
Density correction
0.91
Industrial machinery and mobile equipment can cause fatal injuries. Use these estimates for preliminary sizing. Follow the MSHA or OSHA requirements that apply at your site. Guard moving parts and nip points, and use site lockout/tagout and hazardous-energy isolation procedures before service. Have qualified personnel verify equipment selection and operating limits.
{"tool":{"id":"screen","anatomy":"Screen deck and material split","metrics":[["area","Required live deck area","area","DECK AREA"],["efficiency","Estimated passing efficiency","percent","PASS EFF."],["passing","Undersize product","massRate","UNDERSIZE"],["retained","Oversize product","massRate","OVERSIZE"],["fines","True undersize in feed","massRate"],["missed","Undersize retained on deck","massRate"],["area90","Deck area at 90% recovery","area"],["baseRate","Aperture base capacity","deckRate"],["rating","Corrected unit capacity","deckRate"],["oversizeFactor","Oversize correction","count"],["halfFactor","Half-size correction","count"],["deckFactor","Deck position correction","count"],["wetFactor","Wet screening correction","count"],["densityFactor","Density correction","count"]],"fields":[{"key":"feed","label":"Feed rate","kind":"massRate","initial":217.7243376,"min":0.009071847400000001,"max":27215.5422},{"key":"undersize","label":"Undersize in feed","kind":"percent","initial":68,"min":1,"max":100},{"key":"half","label":"Half-size in feed","kind":"percent","initial":36,"min":0,"max":100,"help":"Percent of total feed smaller than half the selected aperture."},{"key":"aperture","label":"Screen aperture","kind":"size","initial":0.019049999999999997,"min":0.000381,"max":0.2032},{"key":"density","label":"Bulk density","kind":"density","initial":1601.8463373960137,"min":16.018463373960138,"max":6407.385349584055},{"key":"deck","label":"Deck position","initial":"top","options":[["top","Top deck"],["second","Second deck"],["third","Third deck"]]},{"key":"wet","label":"Screening mode","initial":"dry","options":[["dry","Dry"],["wet","Wet with spray"]]},{"key":"installed","label":"Installed live deck area","kind":"area","initial":7.803855360000001,"min":0.009290304000000001,"max":222.967296},{"key":"target","label":"Target passing efficiency","kind":"percent","initial":90,"min":1,"max":99.9},{"key":"baseRate","label":"OEM base screen rating","kind":"deckRate","initial":0,"min":0,"max":976.48552727661,"group":"factors","help":"0 uses the aperture curve. Enter the passing capacity per unit area at the stated reference conditions."}]},"initial":{"feed":95.2543977,"undersize":63,"half":32,"aperture":0.004762499999999999,"density":1457.6801670303726,"deck":"third","wet":"dry","installed":7.339340160000001,"target":92,"baseRate":0},"title":"Dry fines on a third deck","route":"/vibrating-screen-calculator/third-deck-fines/"}