Cement silo pulse-jet bags

A cement collector specifies a vendor design ratio and an existing 48-bag online configuration.

Inputs

Collector duty
m³/h
m/min
Use 0 for the midpoint of the screening band. Enter the supplier’s design ratio when available.
Filter & housing
mm
m
Use 0 to size the online count.
m²
m/s
Use the collector supplier’s limit for this dust.

Live results

Collector air path and media loading

Collector air path and media loadingEXHAUST FLOW9,500m³/hAIR-TO-CLOTH2.692m/minONLINE COUNT48unitsCAN VELOCITY0.3449m/sDusty inletFiltered airPulse jetCan velocityOperating air-to-clothBand 1.219 m/min2.692 m/minHigh 2.438 m/min
Dusty air enters from the left and passes around the elements. Filtered air exits from the upper plenum.

Operating air-to-cloth is above the selected screening band.

Exhaust flow
9,500 m³/h
Air-to-cloth
2.69226 m/min
Online count
48 units
Can velocity
0.344873 m/s

Media and screening band

Minimum required media
102.151 m²
Media per element
1.22522 m²
Installed online media
58.8106 m²
Recommended online count
84 units
Design air-to-cloth
1.55 m/min
Actual ratio in alternate units
8.83287 ft/min
Screening band low
1.2192 m/min
Screening band high
2.4384 m/min

Can cross-section

Free can area
7.65177 m²
Can velocity
0.344873 m/s
Entered can velocity limit
1.27 m/s

Worked calculation at the starting values

Compare the operating ratio of the installed count with the sizing answer at the entered design ratio.

  1. Required media = 2.638889 ÷ 0.02583333 = 102.1505 m².
  2. Sized online count = round up (102.1505 ÷ 1.225221) = 84.
  3. Installed free can area = 8.5 − 48 × π × 0.15² ÷ 4 = 7.65177 m².
Starting result snapshot
Exhaust flow
9,500 m³/h
Air-to-cloth
2.69226 m/min
Online count
48 units
Can velocity
0.344873 m/s

Equations and assumptions

Media sizing

A_min = Q ÷ (A/C)_design · N_min = ceil(A_min ÷ A_element)

A bag uses the cylindrical length × circumference. Enter the rated pleated media area for a cartridge and its outside diameter separately. Count only filters online during the airflow condition.

Operating air-to-cloth

(A/C)_actual = Q ÷ (N_online × A_element)

CFM per ft² reduces to ft/min. The selectable material and collector bands are preliminary screening estimates informed by industry practice and EPA gas-to-cloth examples. Request vendor values for loading, moisture and cleaning method.

Interstitial can velocity

V_can = Q ÷ (A_can − N_online × π × D² ÷ 4)

Use gross cross-section where upward gas passes the installed elements. Equipment with downflow or crossflow needs a geometry-specific check. A nonpositive net area means the entered elements do not fit this section.

References

More worked examples

Open calculator defaults