Pharmaceutical powder cartridges

A powder transfer enclosure shares a cartridge collector with six online elements.

Inputs

Collector duty
m³/h
m/min
Use 0 for the midpoint of the screening band. Enter the supplier’s design ratio when available.
Filter & housing
mm
m²
Use 0 to size the online count.
m²
m/s
Use the collector supplier’s limit for this dust.

Live results

Collector air path and media loading

Collector air path and media loadingEXHAUST FLOW1,800m³/hAIR-TO-CLOTH0.2632m/minONLINE COUNT6unitsCAN VELOCITY0.2478m/sDusty inletFiltered airPleated mediaCan velocityOperating air-to-clothBand 0.1524 m/min0.2632 m/minHigh 0.381 m/min
Dusty air enters from the left and passes around the elements. Filtered air exits from the upper plenum.

Air-to-cloth and interstitial velocity are within the entered screening limits.

Exhaust flow
1,800 m³/h
Air-to-cloth
0.263158 m/min
Online count
6 units
Can velocity
0.247837 m/s

Media and screening band

Minimum required media
112.486 m²
Media per element
19 m²
Installed online media
114 m²
Recommended online count
6 units
Design air-to-cloth
0.2667 m/min
Actual ratio in alternate units
0.863379 ft/min
Screening band low
0.1524 m/min
Screening band high
0.381 m/min

Can cross-section

Free can area
2.01745 m²
Can velocity
0.247837 m/s
Entered can velocity limit
0.72 m/s

Worked calculation at the starting values

Compare the entered count against the modeled sizing result. Evaluate exposure control and safe change-out separately.

  1. Required media = 0.5 ÷ 0.004445 = 112.4859 m².
  2. Sized online count = round up (112.4859 ÷ 19) = 6.
  3. Installed free can area = 2.5 − 6 × π × 0.32² ÷ 4 = 2.017451 m².
Starting result snapshot
Exhaust flow
1,800 m³/h
Air-to-cloth
0.263158 m/min
Online count
6 units
Can velocity
0.247837 m/s

Equations and assumptions

Media sizing

A_min = Q ÷ (A/C)_design · N_min = ceil(A_min ÷ A_element)

A bag uses the cylindrical length × circumference. Enter the rated pleated media area for a cartridge and its outside diameter separately. Count only filters online during the airflow condition.

Operating air-to-cloth

(A/C)_actual = Q ÷ (N_online × A_element)

CFM per ft² reduces to ft/min. The selectable material and collector bands are preliminary screening estimates informed by industry practice and EPA gas-to-cloth examples. Request vendor values for loading, moisture and cleaning method.

Interstitial can velocity

V_can = Q ÷ (A_can − N_online × π × D² ÷ 4)

Use gross cross-section where upward gas passes the installed elements. Equipment with downflow or crossflow needs a geometry-specific check. A nonpositive net area means the entered elements do not fit this section.