CleanroomVentLab · Calculation sheet · Metric SI
Toluene coating line
Inputs
- Solvent
- Toluene
- Peak evaporation rate
- 8 L/h
- Process basis
- Continuous · 4× (25% LEL)
- Process air temperature
- 160 °C
- Site elevation above sea level
- 0 m
- Temperature correction
- Estimate from temperature
- Available fresh air
- 450 Nm³/h
Results
- Min. fresh air
- 688.843 Nm³/h
- Vapor flow
- 1.69382 Nm³/h
- At avail. flow
- 38.2691 % LEL
- LEL margin
- -13.2691 pp
- Molecular weight
- 92.1 g/mol
- Liquid specific gravity
- 0.87
- Reference LEL
- 1.1 % vol
- Vapor mass rate
- 6.96 kg/h
- Vapor at process conditions
- 2.686 m³/h
- Theoretical airflow at reference LEL
- 153.984 Nm³/h
- Temperature multiplier
- 1.11837 ×
- Temperature-adjusted LEL
- 0.983576 % vol
- Screening factor
- 4 ×
- Target concentration
- 25 % LEL
- Concentration at calculated minimum
- 25 % LEL
- Available fresh air
- 450 Nm³/h
- Estimated ambient pressure
- 101.325 kPa abs
- Minimum actual fresh air
- 1,092.34 m³/h
- Equivalent actual available air
- 713.591 m³/h
Available fresh air is below the modeled target.
For preliminary engineering and EHS / Industrial Hygiene review. Design calculations do not replace review by a licensed professional engineer (PE) and a certified industrial hygienist (CIH), commissioning tests, ISO 14644 classification or certification, or assessment against the applicable NFPA 86 edition.