R = thickness / k • Q = A × (Tambient − Tpayload) / R
Area is measured at the wall mid-plane using interior dimensions plus one wall thickness. This case assumes the cavity follows the payload target. The readout also shows the higher heat leak if the whole cavity approaches the coolant phase temperature.
Coolant consumption
Rate = 3.6 × Q(W) / L(kJ/kg)
Dry ice uses 571 kJ/kg, about 246 BTU/lb, at −78.5 °C. The 0 °C and −21 °C phase-change pack enthalpies are adjustable starting values.
Reserve and qualification
treserve = m / rate × (1 − reserve fraction)
Budget for seams, bridges, air exchange, payload preconditioning, and ambient extremes. Verify the actual pack-out by an instrumented test against its approved qualification protocol and payload limits.
What should I check in the eps dry-ice seafood shipper example?
Compare the reserve-adjusted hold estimate with the modeled colder-cavity heat leak. Use instrumented pack-out qualification to verify the time limit.
ColdChainLab · Engineering calculation
EPS dry-ice seafood shipper
Metric SI · https://calcsheetlab.com/coldchainlab/dry-ice-shipper-hold-time/eps-dry-ice-seafood/
Inputs
Interior length
0.52 m
Interior width
0.36 m
Interior height
0.34 m
Insulation thickness
70 mm
Insulation preset
Expanded polystyrene (EPS)
Effective conductivity
0.035 W/(m·K)
Ambient temperature
32 °C
Payload target temperature
-18 °C
Latent-energy reserve
30 %
Coolant
Dry ice (−78.5 °C)
Coolant mass
8.5 kg
Results
Reserve hold
28.09h
Heat leak
33.6W
Coolant use
0.212kg/h
Nominal hold
40.13h
Mid-wall heat-transfer area
1.34m²
Wall R-value
2m²·K/W
Latent energy available
4,854kJ
Phase-change enthalpy
571kJ/kg
Coolant phase temperature
-78.5°C
Hold time set aside
12.04h
Ambient-to-payload difference
50K
Heat leak with cavity at coolant phase temp.
74.24W
Dry ice releases CO₂. Use packaging designed to vent it and follow the applicable handling and shipping requirements.
Use these estimates for preliminary engineering. Verify results against validated cold-chain qualification protocols, applicable ASHRAE Standards 15 and 34, and local food and pharmaceutical regulations. Use manufacturer data, measured operating conditions, and approved acceptance criteria before acting on a result.