10 kΩ NTC battery temperature divider
An embedded measurement uses a 10 kΩ pull-up and a grounded NTC near a storage module.
Model inputs
- Sensor model
- NTC thermistor
- Known quantity
- Temperature → resistance
- Sensor temperature
- 45 °C
- Thermistor equation
- Beta (B25/85)
- R at 25 °C
- 10000 Ω
- Beta constant
- 3950 K
- Pull-up resistor
- 10000 Ω
- Divider supply
- 3.3 V
Model inputs
Fractional AWG shows the equivalent copper area.
Calibration curves & sensor wiring
NTC model- Temperature
- 45°C
- Resistance
- 4348.1Ω
- Divider
- 1V
- Sensitivity
- −27.199mV/°C
Calculated results
- Sensor temperature
- 45°C
- NTC resistance
- 4348.1Ω
- Divider node (NTC to ground)
- 1V
- Divider sensitivity
- −27.199mV/°C
- NTC reference at 25 °C
- 10000Ω
- Use the sensor vendor’s coefficients and rated temperature range. The divider ignores ADC input loading and heating.
Model and interpretation
Full methodologyUse the nominal platinum curve
A = 3.9083×10⁻³, B = −5.775×10⁻⁷ and C = −4.183×10⁻¹². The nominal range is −200 to 850 °C. Actual probe tolerance, calibration coefficients and certified operating span come from its datasheet.
Budget wiring and self-heating separately
A 2-wire readout includes twice the lead resistance. For 3-wire compensation the residual is modeled as one lead resistance times the signed mismatch percentage. Self-heating is I²R times the supplied temperature rise per mW.
Use the correct sensor family
NTC conversion uses Beta or 1/TK = A + B ln R + C(ln R)³. The divider node sits between a pull-up and the grounded NTC. Thermocouple cold-junction compensation uses a different model and is outside this tool.