CorrosionRateLab
Menu

2507 super duplex seawater candidate

A 2507 heat has typical 25% Cr, 4% Mo and 0.27% N.

Inputs

SI units

Enter mass percent from the material certificate and the wetted areas exposed to the same electrolyte. Presets are typical chemistry.

%
%
%
%
×
mm/yr
PREN
42.52
PREN with W
42.52
Area factor
1 ×
Rate proxy
0.12 mm/yr

Pitting resistance and exposed areas

Schematic
Pitting resistance and exposed areas (schematic, not to scale)Chloride comparison bands<2525–<3232–40>40CathodeActive anodeSchematic wetted areasSTANDARD PREN42.52PREN WITH W42.52AREA RATIO0.65 ×
Low area contrast

Area ratio is a sensitivity screen. Check the galvanic series, electrolyte, temperature, crevices and actual alloy condition.

Cathode to anode area · 10:1 reference

Calculation details

Standard PREN tier
Above 40 · seawater candidate
Tungsten-adjusted tier
Above 40 · seawater candidate
Galvanic area screen
Low area contrast
Area-scaled anode rate
0.12 mm/yr

Worked calculation

Starting values · SI
  1. Cr + 3.3Mo + 16N = 42.52. The tungsten-adjusted number is 42.52.
  2. The standard PREN tier is above 40 · seawater candidate.
  3. Apply the 1× area factor to 0.12 mm/yr for a rate proxy of 0.12 mm/yr.

The high PREN tier supports a closer seawater assessment. Review weld condition and verify crevice resistance at operating temperature.

Method and limits

  1. Calculate each composition index

    Standard PREN = Cr + 3.3Mo + 16N. With tungsten use PREN_W = Cr + 3.3(Mo + 0.5W) + 16N. Enter each element in mass percent.

  2. Read the comparison bands

    The bands are below 25, 25 to below 32, 32 to 40 inclusive, and above 40. The highest band denotes a seawater candidate for further assessment.

  3. Compare the exposed areas

    The proxy multiplies the uncoupled anode rate by max(1, cathode/anode area). Area contrast is low up to 1, raised above 1 through 10, and high above 10. These are comparison bands for the area effect.