Carbon steel Faraday conversion
Electrochemical measurement yielded 22 µA/cm² for a steel specimen. Use an equivalent weight of 27.92 g/equiv.
Inputs
SI unitsUse cleaned mass loss, total exposed area and the actual exposure duration. Equivalent weights in the presets are illustrative.
- Penetration
- 0.26 mm/yr
- Areal loss
- 5.5 g/(m²·day)
- Current equiv.
- 22 µA/cm²
- US rate
- 10.06 mpy
Coupon exposure cell
SchematicThe conversion assumes uniform dissolution at the selected equivalent weight. Confirm alloy valence and current efficiency.
Calculation details
- Metric penetration
- 0.2555 mm/yr
- US penetration
- 10.0607 mpy
- Areal mass-loss rate
- 5.5 g/(m²·day)
- Equivalent corrosion current
- 22 µA/cm²
- mm/yr per µA/cm²
- 0.011616
Inputs used
- Calculation mode
- Current density to rate
- Alloy preset
- Carbon steel
- Alloy density
- 7.86 g/cm³
- Equivalent weight
- 27.92 g/equiv
- Corrosion current
- 22 µA/cm²
Worked calculation
Starting values · SI- The alloy coefficient 0.00327 × 27.92 ÷ 7.86 is 0.01162 mm/yr per µA/cm².
- A current density of 22 µA/cm² corresponds to 0.25554 mm/yr or 10.06073 mpy.
Use the current-derived average rate to compare with a separate coupon test. Different wetting or exposure periods can change the comparison.
Method and limits
Normalize the exposure
Use mass loss W in grams, total exposed area A in cm², duration T in hours and density ρ in g/cm³. Include both faces and edges if these were exposed.
Calculate penetration and areal loss
Average penetration = K × W ÷ (A × T × ρ). K is 87,600 for mm/yr and 3,450,000 for mpy. Areal mass loss = 240,000 × W ÷ (A × T) in g/(m²·day). The two published K values are independently rounded.
Convert using equivalent weight
The Faraday relation is mm/yr = 0.00327 × i × EW/ρ, where i is in µA/cm². Divide by the coefficient to convert back. In either Faraday mode, mpy = mm/yr ÷ 0.0254.