CorrosionRateLab
Menu

Carbon steel Faraday conversion

Electrochemical measurement yielded 22 µA/cm² for a steel specimen. Use an equivalent weight of 27.92 g/equiv.

Inputs

SI units

Use cleaned mass loss, total exposed area and the actual exposure duration. Equivalent weights in the presets are illustrative.

g/cm³
g/equiv
µA/cm²
Penetration
0.26 mm/yr
Areal loss
5.5 g/(m²·day)
Current equiv.
22 µA/cm²
US rate
10.06 mpy

Coupon exposure cell

Schematic
Coupon exposure cell (schematic, not to scale)Exposure bathNet metal lossExposed coupon facesCORROSION CURRENT22 µA/cm²EQUIVALENT WEIGHT27.92 g/equivAREAL LOSS5.5 g/(m²·day)
Faraday equivalent

The conversion assumes uniform dissolution at the selected equivalent weight. Confirm alloy valence and current efficiency.

Reference scale · 0 to 1 mm/yr

Calculation details

Metric penetration
0.2555 mm/yr
US penetration
10.0607 mpy
Areal mass-loss rate
5.5 g/(m²·day)
Equivalent corrosion current
22 µA/cm²
mm/yr per µA/cm²
0.011616

Worked calculation

Starting values · SI
  1. The alloy coefficient 0.00327 × 27.92 ÷ 7.86 is 0.01162 mm/yr per µA/cm².
  2. A current density of 22 µA/cm² corresponds to 0.25554 mm/yr or 10.06073 mpy.

Use the current-derived average rate to compare with a separate coupon test. Different wetting or exposure periods can change the comparison.

Method and limits

  1. Normalize the exposure

    Use mass loss W in grams, total exposed area A in cm², duration T in hours and density ρ in g/cm³. Include both faces and edges if these were exposed.

  2. Calculate penetration and areal loss

    Average penetration = K × W ÷ (A × T × ρ). K is 87,600 for mm/yr and 3,450,000 for mpy. Areal mass loss = 240,000 × W ÷ (A × T) in g/(m²·day). The two published K values are independently rounded.

  3. Convert using equivalent weight

    The Faraday relation is mm/yr = 0.00327 × i × EW/ρ, where i is in µA/cm². Divide by the coefficient to convert back. In either Faraday mode, mpy = mm/yr ÷ 0.0254.