A high-temperature line at 90 °C is evaluated with an assumed 100% protective-scale credit to show the mathematical boundary.

Inputs

SI units

Use absolute pressure and the gas-phase mole fraction. Enter a single measured or assumed net mitigation efficiency.

°C
bar(a)
%
mm/yr
% Enter one independently justified net efficiency.
Mitigated rate
0 mm/yr
Baseline rate
27.408 mm/yr
CO₂ partial
3.66 bar(a)
CO₂ fugacity
3.292 bar(a)

Gas, wet steel and mitigation boundary

Schematic
Gas, wet steel and mitigation boundary (schematic, not to scale)CO₂ gasWater-wet carbon steelWet steel boundaryNet credit shown in cyanCO₂ PARTIAL3.66 bar(a)FUGACITY3.292 bar(a)MITIGATED RATE0 mm/yr
Full mitigation credit entered

A zero model term gives a zero output. Verify the assumptions and assess other active corrosion mechanisms.

Mitigated rate ÷ selected screening target

Calculation details

Absolute temperature
363.15 K
Partial pressure
3.66 bar(a)
Fugacity coefficient
0.89936
Corrected CO₂ fugacity
3.2917 bar(a)
Remaining modeled rate fraction
0 %
Modeled rate reduction
27.408 mm/yr
Mitigated metric rate
0 mm/yr
Mitigated US rate
0 mpy

Worked calculation

Starting values · SI
  1. The gas fraction gives 3.66 bar(a) partial pressure. The fugacity coefficient is 0.89936.
  2. The calculated CO₂ fugacity is 3.29167 bar(a) and the baseline rate is 27.4076 mm/yr.
  3. The 100% net efficiency gives 0 mm/yr, or 0 mpy.

The modeled mitigated rate becomes zero while the uninhibited rate remains measurable. Confirm film performance under operating transients.

Method and limits

  1. Find CO₂ partial pressure

    Multiply absolute pressure in bar by the gas-phase CO₂ mole fraction. Convert temperature to kelvin before evaluating either equation.

  2. Correct for fugacity

    log₁₀(a) = (0.0031 − 1.4/T_K) × P_bar. The fugacity f is a × P_CO₂. The uninhibited rate is 10^[5.8 − 1710/T_K + 0.67 log₁₀(f)] in mm/yr. Zero CO₂ gives a zero term directly.

  3. Apply the chosen net credit

    Multiply by (1 − η), where η is the credited efficiency fraction for a pH effect, protective scale, inhibitor or their measured combined effect. Convert mm/yr to mpy by dividing by 0.0254.